english Icono del idioma   español Icono del idioma  

Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/20.500.12008/43531 Cómo citar
Título: Measurement of knee articulation looseness by videofluoroscopy image analysis : CINARTRO
Autor: Simini, Franco
Santos, Darío
Artigas, José
Gigirey, Verónica
Dibarboure, Luis
Francescoli, Luis
Tipo: Ponencia
Palabras clave: Knee Kinematics, Tibio femoral contact point, Quadriceps moment arm, CINARTRO
Descriptores: Sistemas y Control
Fecha de publicación: 2017
Resumen: The yearly incidence of injured Anterior Cruciate Ligament is one every 3000 persons. Usual clinical evaluation methods are qualitative and thus of limited value for precise follow-up either after surgical or conservative medical conduct. Additionally, routine Anterior Cruciate Ligament evaluation is static, overlooking any dynamic behavior of the knee. In research settings, several methods are used to evaluate knee articulation during movement, such as the Tibio Femoral Contact Point migration or the Instantaneous Centre of Rotation displacement and even the Moment Arm variations during extension. We have devised a novel instrument based on 30 images extracted from knee extension videofluoroscopy, which are interactively analyzed to allow automatic determination of kinematics parameters. The instrument, called CINARTRO, compares values with the contralateral knee and produces a standard Clinical Document Architecture file ready for Electronic Medical Record systems. Proof of concept of CINARTRO was set up using videofluroscopy and computer devices. To correct the “pin cushion” effect of X ray intensifiers, a 10 mm apart lead sphere phantom was developed to calibrate images. To validate the interactive selection of anatomical points on X ray images, a cadaveric leg was marked with lead markers and compared with points marked on the blind image, giving good precision measurements. Anterior Cruciate Ligament and contralateral parameters are given for a series of 6 patients, otherwise healthy amateur and professional soccer players.
Descripción: Trabajo presentado al IEEE International Instrumentation and Measurement Technology Conference (I2MTC), Turin, Italy, 22-25 may., 2017
Citación: Simini, F, Santos, D, Artigas, A, Gigirey, V, Dibarboure, L, Francescoli, L. "Measurement of knee articulation looseness by videofluoroscopy image analysis: CINARTRO" Publicado en: Proceedings of the IEEE International Instrumentation and Measurement Technology Conference (I2MTC), Turin, Italy, 22-25 may., 2017, doi: 10.1109/I2MTC.2017.7969820.
Licencia: Licencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0)
Aparece en las colecciones: Publicaciones académicas y científicas - Instituto de Ingeniería Eléctrica

Ficheros en este ítem:
Fichero Descripción Tamaño Formato   
SSAGDF17.pdf512,59 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons