english Icono del idioma   español Icono del idioma  

Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/20.500.12008/43531 Cómo citar
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorSimini, Francoes
dc.contributor.authorSantos, Daríoes
dc.contributor.authorArtigas, Josées
dc.contributor.authorGigirey, Verónicaes
dc.contributor.authorDibarboure, Luises
dc.contributor.authorFrancescoli, Luises
dc.date.accessioned2024-04-16T16:21:15Z-
dc.date.available2024-04-16T16:21:15Z-
dc.date.issued2017es
dc.date.submitted20240416es
dc.identifier.citationSimini, F, Santos, D, Artigas, A, Gigirey, V, Dibarboure, L, Francescoli, L. "Measurement of knee articulation looseness by videofluoroscopy image analysis: CINARTRO" Publicado en: Proceedings of the IEEE International Instrumentation and Measurement Technology Conference (I2MTC), Turin, Italy, 22-25 may., 2017, doi: 10.1109/I2MTC.2017.7969820.es
dc.identifier.urihttps://hdl.handle.net/20.500.12008/43531-
dc.descriptionTrabajo presentado al IEEE International Instrumentation and Measurement Technology Conference (I2MTC), Turin, Italy, 22-25 may., 2017es
dc.description.abstractThe yearly incidence of injured Anterior Cruciate Ligament is one every 3000 persons. Usual clinical evaluation methods are qualitative and thus of limited value for precise follow-up either after surgical or conservative medical conduct. Additionally, routine Anterior Cruciate Ligament evaluation is static, overlooking any dynamic behavior of the knee. In research settings, several methods are used to evaluate knee articulation during movement, such as the Tibio Femoral Contact Point migration or the Instantaneous Centre of Rotation displacement and even the Moment Arm variations during extension. We have devised a novel instrument based on 30 images extracted from knee extension videofluoroscopy, which are interactively analyzed to allow automatic determination of kinematics parameters. The instrument, called CINARTRO, compares values with the contralateral knee and produces a standard Clinical Document Architecture file ready for Electronic Medical Record systems. Proof of concept of CINARTRO was set up using videofluroscopy and computer devices. To correct the “pin cushion” effect of X ray intensifiers, a 10 mm apart lead sphere phantom was developed to calibrate images. To validate the interactive selection of anatomical points on X ray images, a cadaveric leg was marked with lead markers and compared with points marked on the blind image, giving good precision measurements. Anterior Cruciate Ligament and contralateral parameters are given for a series of 6 patients, otherwise healthy amateur and professional soccer players.es
dc.languageenes
dc.rightsLas obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad De La República. (Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014)es
dc.subjectKnee Kinematicses
dc.subjectTibio femoral contact pointes
dc.subjectQuadriceps moment armes
dc.subjectCINARTROes
dc.subject.otherSistemas y Controles
dc.titleMeasurement of knee articulation looseness by videofluoroscopy image analysis : CINARTROes
dc.typePonenciaes
dc.rights.licenceLicencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0)es
Aparece en las colecciones: Publicaciones académicas y científicas - Instituto de Ingeniería Eléctrica

Ficheros en este ítem:
Fichero Descripción Tamaño Formato   
SSAGDF17.pdf512,59 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons