Por favor, use este identificador para citar o enlazar este ítem:
https://hdl.handle.net/20.500.12008/41157
Cómo citar
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Guichon, Michelle | es |
dc.contributor.author | Melo, Magdalena | es |
dc.contributor.author | Nieto, Ana Carolina | es |
dc.contributor.author | Vignolo, Mario | es |
dc.contributor.author | Yedrzejewski, Nicolás | es |
dc.date.accessioned | 2023-11-14T17:04:34Z | - |
dc.date.available | 2023-11-14T17:04:34Z | - |
dc.date.issued | 2012 | es |
dc.date.submitted | 20231114 | es |
dc.identifier.citation | Guichon, M, Melo, M, Nieto, A,Vignolo, M, Yedrzejewski, N. "Automatic load shedding calculated with genetic algorithms – DAC-CMAG" Proceedings of the Sixth IEEE/PES Transmission and Distribution: Latin America Conference and Exposition (T | es |
dc.identifier.citation | D-LA). Monte video, Uruguay, 3-5 set. 2012. | es |
dc.identifier.uri | https://hdl.handle.net/20.500.12008/41157 | - |
dc.description.abstract | This paper presents an optimization tool based on Genetic Algorithms, DAC-CMAG (Automatic Load Shedding Calculated Through Genetic Algorithms), developed in Matlab and applied to the calculation of load shedding in Electric Power Systems. This application calculates the optimal load shed necessary to eliminate overloading of any series element of an electrical network. It includes a module that runs DC load flow to calculate the power flow for each branch or transformer and verifies there are no current violations in any equipment. The results are analyzed using this tool applied to the calculation of optimum load shed required for the worst contingencies in the 500kV power system of Uruguay. | es |
dc.language | en | es |
dc.publisher | Power Engineering Society and IEEE Uruguay Section | es |
dc.relation.ispartof | Sixth IEEE/PES Transmission and Distribution: Latin America Conference and Exposition (T | es |
dc.relation.ispartof | D-LA). Montevideo, Uruguay, 2-5 set. 201|2 | es |
dc.rights | Las obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad De La República. (Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014) | es |
dc.subject | DC load flow | es |
dc.subject | Load shedding | es |
dc.subject | Genetic algorithm | es |
dc.subject.other | Potencia | es |
dc.title | Automatic load shedding calculated with genetic algorithms – DAC-CMAG | es |
dc.type | Ponencia | es |
dc.rights.licence | Licencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0) | es |
udelar.academic.department | Potencia | - |
udelar.investigation.group | Redes Eléctricas | - |
Aparece en las colecciones: | Publicaciones académicas y científicas - Instituto de Ingeniería Eléctrica |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | ||
---|---|---|---|---|---|
GMNVY12.pdf | 345,62 kB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons