english Icono del idioma   español Icono del idioma  

Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/20.500.12008/51171 Cómo citar
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorRodríguez-Muñoz, Juan M.-
dc.contributor.authorBove, Italo-
dc.contributor.authorAlonso-Suárez, Rodrigo-
dc.date.accessioned2025-08-20T12:45:57Z-
dc.date.available2025-08-20T12:45:57Z-
dc.date.issued2026-
dc.identifier.citationRodríguez-Muñoz, J., Bove, I. y Alonso-Suárez, R. Experimental characterization of the diffuse incident angle modifier of solar thermal collectors: improving consistency between test methods [Preprint] Publicado en : Renewable Energy 256(C):123912, 2026. DOI : https://doi.org/10.1016/j.renene.2025.123912.es
dc.identifier.urihttps://hdl.handle.net/20.500.12008/51171-
dc.description.abstractDiffuse solar irradiance is essential for modeling solar energy conversion devices, especially solar thermal collectors. The globally accepted ISO 9806:2017 standard defines a thermodynamic model and two test methods to determine its parameters, the steady-state test (SST) and the quasi-dynamic test (QDT). Although both methods are generally considered equivalent, discrepancies between the values of the diffuse incident angle modifier (IAM) have been reported, representing an area for improvement. This study advances the experimental characterization of diffuse IAM, specifically improving the compatibility between SST and QDT methods. Using the ISO 9806:2017 model as a baseline, two alternative diffuse IAM models are introduced and experimentally evaluated with data from a flat plate collector and an evacuated tube collector, covering different technologies. Model 1 extends the SST diffuse IAM model to QDT and treats diffuse irradiance in a global manner, while Model 2 treats diffuse irradiance from sky and ground separately, requiring an additional solar measurement. The evaluation shows that both proposed models improve the consistency between test methods. As the performance differences between these two new models are minimal, Model 1 is the recommended option as its implementation is simpler.es
dc.format.extent26 p.es
dc.format.mimetypeapplication/pdfes
dc.language.isoenes
dc.rightsLas obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad de la República.(Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014)es
dc.subjectSolar thermal collectores
dc.subjectDiffuse incident angle modifieres
dc.subjectGround albedoes
dc.subjectISO 9806 standardes
dc.titleExperimental characterization of the diffuse incident angle modifier of solar thermal collectors: improving consistency between test methods.es
dc.typePreprintes
dc.contributor.filiacionRodríguez-Muñoz Juan M., Laboratorio de Energía Solar, Departamento de Física del Litoral, CENUR Litoral Norte, Universidad de la República, Uruguay-
dc.contributor.filiacionBove Italo, Universidad de la República (Uruguay). Facultad de Ingeniería.-
dc.contributor.filiacionAlonso-Suárez Rodrigo, Universidad de la República (Uruguay). Facultad de Ingeniería.-
dc.rights.licenceLicencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0)es
Aparece en las colecciones: Publicaciones académicas y científicas - Laboratorio de Energía Solar (LES)

Ficheros en este ítem:
Fichero Descripción Tamaño Formato   
RBA26.pdfPreprint2,9 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons