Por favor, use este identificador para citar o enlazar este ítem: 
                
           
                 
                
    
    https://hdl.handle.net/20.500.12008/43476 
                
                
                Cómo citar
                | Título: | Efecto del voltaje y electrolito en la morfología y comportamiento a la corrosión de capas nanoestructuradas de TiO2en sustratos de Ti6Al4Vpara uso biomédico | 
| Otros títulos: | Effect of voltage and electrolyte on the morphology and corrosion behavior of nanostructured layers of TiO2in Ti6Al4V substrates for biomedical use | 
| Autor: | Correia, M. Gil, L. E. Angulo, N Méndez, Eduardo Pereyra, Mariana | 
| Tipo: | Artículo | 
| Palabras clave: | Titanio, Anodizado, Voltaje, Electrolito, Resistencia a la corrosión, Titanium, Anodized, Voltage, Electrolyte, Corrosion resistance | 
| Fecha de publicación: | 2022 | 
| Resumen: | El  uso  del titanio  como  biomaterial  se  ha  traducido  en  un  avance  en  la  ciencia  e  ingeniería,  puesto  que  permite  la fabricación  de  prótesis  medicas  con  mayor  tiempo  de  vida  útil  junto  con  un  incremento  en  la  esperanza  de  vida  de  los pacientes.  Sin  embargo,  se  ha  demostrado  que  la  pasivación de  la  aleacion  Ti6Al4V a  través  del  proceso  de  anodizado electroquímico  mejora  las propiedades del material base debido  a la formación deuna  capa  de nanotubos de dióxido de titanio (TiO2). Por tal motivo en la presente investigacion se evaluara el efecto de la variación del tipo de electrolito y del voltaje empleado en la formación de las nanoestructuras y su resistencia a la corrosión. Se obtuvieron nanotubos a partir de un  electrolito  de  tercera  generación  con  diámetros  internos  de  109,36  y  131,95  nm,  espesor  de  20,29 y  29,76  nm,respectivamentemientras que utilizandoun electrolito de cuarta generación no se obtuvo una capa tubular, debido a la poca estabilidad  del  ion  Ti4+en  la  formación  de  compuestos  intermedios.  Adicionalmente,  se  comprobó  que  los  procesos  de anodizado en las cuatro condiciones en estudio mejoran la resistencia a la corrosión, puesto que se obtiene una disminuciónenla velocidad de corrosion de hasta del 26%, disminuyendo de 0,43mmpyen la condición de partida hasta un 0,11 mmpy para los nanotubos fabricados a través de anodizado de tercera generación, lo cual aunadoa los requerimientos de diámetro óptimo permite que la pieza cumpla su función en las aplicaciones biomédicas. The use of titanium as a biomaterial has resulted in an advance in science and engineering, since it allows the manufacture of medical prostheses with a longer useful life together with an increase in the life expectancy of patients. However, it has been shown that passivation through the electrochemical anodizing process improves the properties of the base material through the formation of titanium dioxide (TiO2) nanotubes, so it is desired to study the variation of the type of electrolyte and voltage used in the formation of nanostructures and their resistance to corrosion. Nanotubes were obtained from a third generation electrolyte with internal diameters of 109.36 and 131.95 nm, thickness of 20.29 and 29.76 nm, on the other hand, in the process with a fourth generation electrolyte, no tubular layer, due to the poor stability of the Ti4+ion in the formation of intermediate compounds. Additionally, it was found that the anodizing processes in the four conditions under study improve corrosion resistance, since a decrease in the corrosion rate of up to 26% is obtained, decreasing from 0.43 mmpy in the starting condition. up to 0.11 mmpy for nanotubes manufacturedthrough third-generation anodizing, which, together with the optimal diameter requirements, allows the piece to fulfill its function in biomedical applications. | 
| Descripción: | Ponencia presentada en: XIX CONVEMI - Congreso Venezolano de Microscopía y Microanálisis. | 
| Editorial: | Comité Interamericano de Sociedades de Microscopía Electrónica | 
| EN: | Acta Microscópica, 2022, 31(1): 21-32. | 
| Citación: | Correia, M, Gil, L, Angulo, N [y otros autores]. "Efecto del voltaje y electrolito en la morfología y comportamiento a la corrosión de capas nanoestructuradas de TiO2en sustratos de Ti6Al4Vpara uso biomédico". Acta Microscópica. [en línea] 2022, 31(1): 21-32. 12 h. | 
| ISSN: | 2310-2799 | 
| Licencia: | Licencia Creative Commons Atribución - No Comercial (CC - By-NC 4.0) | 
| Aparece en las colecciones: | Publicaciones académicas y científicas - Facultad de Ciencias | 
Ficheros en este ítem: 
| Fichero | Descripción | Tamaño | Formato | ||
|---|---|---|---|---|---|
| Efecto del voltaje y electrolito en la morfología y comportamiento a la corrosión de capas nanoestructuradas de TiO2 en sustratos de Ti6Al4V para uso biomédico.pdf | 818,12 kB | Adobe PDF | Visualizar/Abrir | 
Este ítem está sujeto a una licencia Creative Commons  Licencia Creative Commons 
     
    
 
        
                    