english Icono del idioma   español Icono del idioma  

Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/20.500.12008/43476 Cómo citar
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorCorreia, M.-
dc.contributor.authorGil, L. E.-
dc.contributor.authorAngulo, N-
dc.contributor.authorMéndez, Eduardo-
dc.contributor.authorPereyra, Mariana-
dc.date.accessioned2024-04-15T13:52:39Z-
dc.date.available2024-04-15T13:52:39Z-
dc.date.issued2022-
dc.identifier.citationCorreia, M, Gil, L, Angulo, N [y otros autores]. "Efecto del voltaje y electrolito en la morfología y comportamiento a la corrosión de capas nanoestructuradas de TiO2en sustratos de Ti6Al4Vpara uso biomédico". Acta Microscópica. [en línea] 2022, 31(1): 21-32. 12 h.es
dc.identifier.issn2310-2799-
dc.identifier.urihttps://hdl.handle.net/20.500.12008/43478-
dc.descriptionPonencia presentada en: XIX CONVEMI - Congreso Venezolano de Microscopía y Microanálisis.es
dc.description.abstractEl uso del titanio como biomaterial se ha traducido en un avance en la ciencia e ingeniería, puesto que permite la fabricación de prótesis medicas con mayor tiempo de vida útil junto con un incremento en la esperanza de vida de los pacientes. Sin embargo, se ha demostrado que la pasivación de la aleacion Ti6Al4V a través del proceso de anodizado electroquímico mejora las propiedades del material base debido a la formación deuna capa de nanotubos de dióxido de titanio (TiO2). Por tal motivo en la presente investigacion se evaluara el efecto de la variación del tipo de electrolito y del voltaje empleado en la formación de las nanoestructuras y su resistencia a la corrosión. Se obtuvieron nanotubos a partir de un electrolito de tercera generación con diámetros internos de 109,36 y 131,95 nm, espesor de 20,29 y 29,76 nm,respectivamentemientras que utilizandoun electrolito de cuarta generación no se obtuvo una capa tubular, debido a la poca estabilidad del ion Ti4+en la formación de compuestos intermedios. Adicionalmente, se comprobó que los procesos de anodizado en las cuatro condiciones en estudio mejoran la resistencia a la corrosión, puesto que se obtiene una disminuciónenla velocidad de corrosion de hasta del 26%, disminuyendo de 0,43mmpyen la condición de partida hasta un 0,11 mmpy para los nanotubos fabricados a través de anodizado de tercera generación, lo cual aunadoa los requerimientos de diámetro óptimo permite que la pieza cumpla su función en las aplicaciones biomédicas.es
dc.description.abstractThe use of titanium as a biomaterial has resulted in an advance in science and engineering, since it allows the manufacture of medical prostheses with a longer useful life together with an increase in the life expectancy of patients. However, it has been shown that passivation through the electrochemical anodizing process improves the properties of the base material through the formation of titanium dioxide (TiO2) nanotubes, so it is desired to study the variation of the type of electrolyte and voltage used in the formation of nanostructures and their resistance to corrosion. Nanotubes were obtained from a third generation electrolyte with internal diameters of 109.36 and 131.95 nm, thickness of 20.29 and 29.76 nm, on the other hand, in the process with a fourth generation electrolyte, no tubular layer, due to the poor stability of the Ti4+ion in the formation of intermediate compounds. Additionally, it was found that the anodizing processes in the four conditions under study improve corrosion resistance, since a decrease in the corrosion rate of up to 26% is obtained, decreasing from 0.43 mmpy in the starting condition. up to 0.11 mmpy for nanotubes manufacturedthrough third-generation anodizing, which, together with the optimal diameter requirements, allows the piece to fulfill its function in biomedical applications.es
dc.format.extent12 h.es
dc.format.mimetypeapplication/pdfes
dc.language.isoeses
dc.publisherComité Interamericano de Sociedades de Microscopía Electrónicaes
dc.relation.ispartofActa Microscópica, 2022, 31(1): 21-32.es
dc.rightsLas obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad de la República.(Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014)es
dc.subjectTitanioes
dc.subjectAnodizadoes
dc.subjectVoltajees
dc.subjectElectrolitoes
dc.subjectResistencia a la corrosiónes
dc.subjectTitaniumes
dc.subjectAnodizedes
dc.subjectVoltagees
dc.subjectElectrolytees
dc.subjectCorrosion resistancees
dc.titleEfecto del voltaje y electrolito en la morfología y comportamiento a la corrosión de capas nanoestructuradas de TiO2en sustratos de Ti6Al4Vpara uso biomédicoes
dc.title.alternativeEffect of voltage and electrolyte on the morphology and corrosion behavior of nanostructured layers of TiO2in Ti6Al4V substrates for biomedical usees
dc.typeArtículoes
dc.contributor.filiacionCorreia M.-
dc.contributor.filiacionGil L. E.-
dc.contributor.filiacionAngulo N-
dc.contributor.filiacionMéndez Eduardo, Universidad de la República (Uruguay). Facultad de Ciencias. Instituto de Química Biológica.-
dc.contributor.filiacionPereyra Mariana, Universidad de la República (Uruguay). Facultad de Ciencias. Centro de Investigaciones Nucleares.-
dc.rights.licenceLicencia Creative Commons Atribución - No Comercial (CC - By-NC 4.0)es
Aparece en las colecciones: Publicaciones académicas y científicas - Facultad de Ciencias
Publicaciones académicas y científicas - Facultad de Ciencias



Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons