Título: Improving N-Wire Phantom-based Freehand Ultrasound Calibration
Autor: Fichtinger, Gabor
Gómez, Alvaro
Lasso, Andras
Carbajal, Guillermo
Tipo: Preprint
Palabras clave: Freehand ultrasound, Calibration, N-wire phantom, Accuracy
Descriptores: Procesamiento de Señales
Fecha de publicación: 2013
Resumen: Purpose Freehand tracked ultrasound imaging is an inexpensive non-invasive technique used in several guided interventions. This technique requires spatial calibration between the tracker and the ultrasound image plane. Several calibration devices (a.k.a. phantoms) use N-wires that are convenient for automatic procedures since the segmentation of fiducials in the images and the localization of the middle wires in space are straightforward and can be performed in real time. The procedures reported in literature consider only the spatial position of the middle wire. We investigate if better results can be achieved if the information of all the wires is equally taken into account. We also evaluated the precision and accuracy of the implemented methods to allow comparison with other methods. Methods We consider a cost function based on the in-plane errors between the intersection of all the wires with the image plane and their respective segmented points in the image. This cost function is minimized iteratively starting from a seed computed with a closed-form solution based on the middle wires. Results Mean calibration precision achieved with the N-wire phantom was about 0.5mm using a shallow probe, and mean accuracy was around 1.4mm with all implemented methods. Precision was about 2.0mm using a deep probe. Conclusions Precision and accuracy achieved with the N-wire phantom and a shallow probe are at least comparable to that obtained with other methods traditionally considered more precise. Calibration using N-wires can be done more consistently if the parameters are optimized with the proposed cost function.
Citación: Carbajal, G, Lasso, A, Gómez, Á. Fichtinger, G. "Improving N-wire phantom-based freehand ultrasound calibration". International Journal of Computer Assisted Radiology and Surgery 2013, no.8, pp. 1063–1072. https://doi.org/10.1007/s11548-013-0904-9
Licencia: Licencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0)
Aparece en las colecciones: Publicaciones académicas y científicas - Instituto de Ingeniería Eléctrica

Ficheros en este ítem:
Fichero Descripción Tamaño Formato   
CLGF13b.pdf868,4 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons