english Icono del idioma   español Icono del idioma  

Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/20.500.12008/41254 Cómo citar
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorBouchacourt, Juan Pablo-
dc.contributor.advisorRiva, Juan-
dc.contributor.authorCristiani, Federico-
dc.date.accessioned2023-11-15T14:46:55Z-
dc.date.available2023-11-15T14:46:55Z-
dc.date.issued2023-
dc.identifier.citationCristiani F. Evaluación de la concordancia entre las variaciones de la velocidad pico aórtico y velocidad pico carotídeo con la ventilación mecánica en una población pediátrica sometida a cirugía electiva bajo anestesia general [en línea]. Tesis de maestría. Montevideo: Udelar. FM, 2023. 63 p.es
dc.identifier.urihttps://hdl.handle.net/20.500.12008/41254-
dc.description.abstractIntroducción. La variación de la velocidad máxima aórtica con la ventilación mecánica (ΔVpeakAo) ha demostrado ser el mejor predictor de respuesta a volumen en pediatría. Existe evidencia en adultos de que la variación de velocidad máxima de flujo carotídeo (ΔVpeakCar) es predictor de respuesta a fluidos. Al momento es escasa la información sobre este índice en pediatría. Su beneficio se basa en la no-invasividad, y que para su medición no es necesaria la ecocardiografía ni el acceso al tórax del paciente. Objetivo. El objetivo general de este trabajo fue estudiar la correlación y la concordancia de ΔVpeakCar con ΔVpeakAo en una población pediátrica bajo ventilación mecánica. Metodología. Se incluyeron pacientes de 0 a 12 años. Se registraron flujos aórtico y carotídeos máximos y mínimos y se calculó ΔVpeakCar y ΔVpeakAo. Para analizar correlación y concordancia entre las variables se utilizó el test de Pearson, análisis de Bland-Altman y análisis de los 4-cuadrantes. Resultados. Se estudiaron 58 pacientes, 13 lactantes (menores 12 meses), 21 preescolares (12-60 meses) y 24 escolares (mayores a 60 meses). Se observó una correlación significativa entre ΔVpeakAo y ΔVpeakCar (r=0,85; p<0,05) con un coeficiente de determinación de r2=0,72. El análisis de Bland-Altman mostró un sesgo del 0,15% (IC95%, -0.7-1.0) con un límite de concordancia del -6,1 a 6,2%. La concordancia fue 85%, con un sesgo angular de 4,5°±31°. El análisis por subgrupos mostró un r2 de 0.89 en escolares, 0.56 en preescolares y 0.45 en lactantes. La concordancia fue de 100% en escolares, 95% en prescolares y 93% en lactantes. Discusión y conclusiones. El registro de ΔVpeakCar fue viable. Al analizar la capacidad de ΔVpeakCar de sustituir a ΔVpeakAo en el total de la muestra, no es buena La correlación y concordancia son mejores en escolares. Es necesario continuar estudiando este nuevo índice.es
dc.description.abstractIntroduction. The variation in maximum aortic velocity with mechanical ventilation (ΔVpeakAo) has proven to be the most effective predictor of fluid response in pediatrics. While there is evidence in adults that the variation in maximum carotid flow velocity (ΔVpeakCar) predicts fluid response, information on this index in pediatrics remains limited. Its advantage lies in its non-invasive nature, eliminating the need for echocardiography or thoracic access for recording. Objective. This study aims to examine the correlation and concordance between ΔVpeakCar and ΔVpeakAo in a pediatric population. Methodology. The study included patients aged 0 to 12 years. Maximum and minimum aortic and carotid flows were recorded, and ΔVpeakCar and ΔVpeakAo were calculated. Correlation and agreement between variables were analyzed using the Pearson test, Bland Altman analysis, and 4-quadrant analysis. Results. A total of 58 patients were studied, comprising 13 infants (under 12 months), 21 preschoolers (12-60 months), and 24 school-aged children (over 60 months). A significant correlation was observed between ΔVpeakAo and ΔVpeakCar (r=0.85; p<0.05) with a coefficient of determination, r²=0.72. The Bland-Altman analysis revealed a bias of 0.15% (95% CI, -0.7-1.0) with an agreement limit of -6.1% to 6.2%. The concordance rate was 85%, with an angular bias of 4.5°±31°. Subgroup analysis showed r² values of 0.89 in school-aged children, 0.56 in preschoolers, and 0.45 in infants. Concordance rates were 100% in school-aged children, 95% in preschoolers, and 93% in infants. Discussion and Conclusions. The measurement of ΔVpeakCar proved feasible. However, when considering its ability to replace ΔVpeakAo, the results are suboptimal. Correlation and concordance are stronger in school-aged children. Further investigation into this new index is warranted.es
dc.description.tableofcontentsA- RESUMEN 7 -- B- MARCO TEÓRICO 9 -- B1. Evaluación hemodinámica en pediatría 9 -- B2. Uso de índices dinámicos de respuesta a fluidos 15 -- B3. Índices dinámicos medidos por ecocardiografía 23 -- B4. Variación de velocidad máxima del flujo carotídeo 27 -- B5. Limitaciones de los índices dinámicos 28 -- B6. Índices dinámicos en pediatría 29 -- B7. Doppler carotídeo y respuesta a fluidos en pediatría 33 -- C- DISEÑO DEL PROYECTO DE INVESTIGACIÓN 35 -- C1. Hipótesis 35 -- C2. Objetivos 35 -- C3. Metodología 35 -- D- RESULTADOS 40 -- E- DISCUSIÓN 50 -- F- CONCLUSIÓN 54 -- G- PERSPECTIVAS 54 -- H- REFERENCIAS BIBLIOGRÁFICAS 55es
dc.format.extent63 p.es
dc.format.mimetypeapplication/vnd.oasis.opendocument.textes
dc.language.isoeses
dc.publisherUdelar. FMes
dc.rightsLas obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad de la República.(Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014)es
dc.subjectDoppler carotídeoes
dc.subjectRespuesta a fluidoses
dc.subjectMonitorización hemodinámicaes
dc.subjectPediatríaes
dc.subjectReposición con fluidoses
dc.subjectChildrenes
dc.subjectDoppler ultrasoundes
dc.subjectFluid responsivenesses
dc.subjectFluid therapyes
dc.subjectHemodynamic monitoringes
dc.subject.otherULTRASONOGRAFÍA DOPPLERes
dc.subject.otherPROCEDIMIENTOS QUIRÚRGICOS ELECTIVOSes
dc.subject.otherTÉCNICAS DE DIAGNÓSTICO CARDIOVASCULARes
dc.subject.otherFLUIDOTERAPIAes
dc.subject.otherMONITOREO INTRAOPERATORIOes
dc.subject.otherCIRUGÍAes
dc.titleEvaluación de la concordancia entre las variaciones de la velocidad pico aórtico y velocidad pico carotídeo con la ventilación mecánica en una población pediátrica sometida a cirugía electiva bajo anestesia general.es
dc.typeTesis de maestríaes
dc.contributor.filiacionCristiani Federico, Universidad de la República (Uruguay). Facultad de Medicina-
thesis.degree.grantorUniversidad de la República (Uruguay). Facultad de Medicina. PROINBIOes
thesis.degree.nameMagíster en Ciencias Médicases
dc.rights.licenceLicencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0)es
Aparece en las colecciones: Tesis de Posgrado - PROINBIO

Ficheros en este ítem:
Fichero Descripción Tamaño Formato   
TMCristianiF.pdfEvaluación de la concordancia entre las variaciones de la velocidad pico aórtico y velocidad pico carotídeo con la ventilación mecánica en una población pediátrica sometida a cirugía electiva bajo anestesia general964,11 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons