english Icono del idioma   español Icono del idioma  

Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/20.500.12008/56378 Cómo citar
Título: Isometric Force-Time Curve Assessment: Accuracy, Precision, and Repeatability of a Mobile Application and Portable and Lightweight Device
Autor: Santos, Darío
Bravo-Sánchez, Alfredo
Peyré-Tartaruga, Leonardo Alexandre
Simini, Franco
Zacca, Rodrigo
Tipo: Artículo
Palabras clave: Digital technologie, Exercise, Exercise physiologie, Health, Physical fitness, Physical therapy, Rehabilitation, Sports biomechanics, Strength assessment
Descriptores: TECNOLOGÍA DIGITAL, APTITID FÍSICA, DEPORTES, REHABILITACIÓN, EJERCICIO FÍSICO, MODALIDADES DE FISIOTERAPIA
Fecha de publicación: 2024
Resumen: Strength assessment is one of the main fields in sports performance, physical rehabilitation, physical activity, and health. We aimed to compare maximal voluntary isometric contractions (MVICs) and paired voluntary isometric contractions (VICs) of knee extensors between an isokinetic dynamometer (BIODEX) and a portable and lightweight device (DINABANG). From 19 volunteers (age: 28.7 ± 7 years; body mass: 72 ± 10 kg; and height: 173 ± 7 cm) we obtained 114 paired MVIC measures and, from the force-time curves of these repetitions, 22,507 paired VIC measures of knee extensors. We observed "excellent" repeatability for MVICs (ICC:1.00; p < 0.001) between BIODEX (247 ± 79.5 Nm) and DINABANG (247 ± 74.8 Nm), with "trivial" effect (mean difference: 0.12 Nm (0.02%); 95%CI: -0.13 to 0.23 Nm; p = 0.606; d = 0.048). Bland-Altman plots revealed high accuracy for MVIC (bias: 0.12 Nm) and consistent distribution (precision) inside the limits of agreement (-4.81 to 5.06 Nm) and respective 95%CI. "Excellent" repeatability was also observed for VICs (ICC:1.00; p < 0.001) between BIODEX (219 ± 84.1 Nm) and DINABANG (218 ± 84.0 Nm), with "trivial" effect (0.24 Nm (0.11%); 0.08 to 0.11 Nm; p < 0.001; d = 0.100). Bland-Altman plots revealed high accuracy for VICs (bias: 0.24 Nm) and consistent distribution (precision) inside the limits of agreement (-4.5 to 4.9 Nm) and respective 95%CI. DINABANG is accurate, precise, and reliable in torque measurement.
Editorial: MDPI
EN: Sports. 2024;12(10)
Citación: Santos D, Bravo-Sánchez A, Peyré-Tartaruga L y otros. Isometric Force-Time Curve Assessment: Accuracy, Precision, and Repeatability of a Mobile Application and Portable and Lightweight Device. Sports [en línea]. 2024;12(10). 9 p.
Licencia: Licencia Creative Commons Atribución (CC - By 4.0)
Aparece en las colecciones: Publicaciones Académicas y Científicas - Facultad de Medicina

Ficheros en este ítem:
Fichero Descripción Tamaño Formato   
Isometric Force-Time Curve Assessment.pdfIsometric Force-Time Curve Assessment4,93 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons