english Icono del idioma   español Icono del idioma  

Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/20.500.12008/55373 Cómo citar
Título: Stroke volume and cardiac output non-invasive monitoring based on brachial oscillometry-derived pulse contour analysis: Explanatory variables and reference intervals throughout life (3-88 years)
Autor: Zócalo, Yanina
García-Espinosa, Victoria
Castro, Juan M.
Zinoveev, Agustina
Marin, Mariana
Chiesa, Pedro
Díaz, Alejandro
Bia, Daniel
Tipo: Artículo
Palabras clave: Adolescents, Adults, Cardiac output, Children, Pulse contour analysis, Reference intervals
Descriptores: GASTO CARDÍACO, ADOLESCENTE, ADULTO, NIÑO, FRECUENCIA CARDÍACA, OSCILOMETRÍA, VALORES DE REFERENCIA, VOLUMEN SISTÓLICO
Fecha de publicación: 2021
Resumen: Background: Non-invasive assessment of stroke volume (SV), cardiac output (CO) and cardiac index (CI) has shown to be useful for the evaluation, diagnosis and/or management of different clinical conditions. Through pulse contour analysis (PCA) cuff‑based oscillometric devices would enable obtaining ambulatory operator-independent non-invasive hemodynamic monitoring. There are no reference intervals (RIs), when considered as a continuum in childhood, adolescence and adult life, for PCA-derived SV [SV(PCA)], CO [CO(PCA)] and CI [CI(PCA)]. The aim of the study were to analyze the associations of SV(PCA), CO(PCA) and CI(PCA) with demographic, anthropometric, cardiovascular risk factors (CVRFs) and hemodynamic parameters, and to define RIs and percentile curves for SV(PCA), CO(PCA) and CI(PCA), considering the variables that should be considered when expressing them. Methods: In 1449 healthy subjects (3-88 years) SV(PCA), CO(PCA) and CI(PCA) were non-invasively obtained (Mobil-O-Graph; Germany). Analysis: associations between subject characteristics and SV(PCA), CO(PCA) and CI(PCA) levels (correlations; regression models); RIs and percentiles for SV(PCA), CO(PCA) and CI(PCA) (parametric methods; fractional polynomials). Results: Sex, age, and heart rate would be explanatory variables for SV, CO, and CI levels. SV levels were also examined by body height, while body surface area (BSA) contributing to evaluation of CO and CI. CVRFs exposure did not contribute to independently explain the values of the dependent variables. SV, CO and CI levels were partially explained by the oscillometric-derived signal quality. RIs and percentiles were defined. Conclusions: Reference intervals and percentile for SV(PCA), CO(PCA) and CI(PCA), were defined for subjects from 3-88 years of age, results are expressed according to sex, age, heart rate, body height and/or BSA.
Editorial: Via Medica
EN: Cardiology Journal. 2021;28(6):864-878
Citación: Zócalo Y, García-Espinosa V, Castro J y otros. Stroke volume and cardiac output non-invasive monitoring based on brachial oscillometry-derived pulse contour analysis: Explanatory variables and reference intervals throughout life (3-88 years). Cardiology Journal [en línea]. 2021;28(6):864-878
Licencia: Licencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0)
Aparece en las colecciones: Publicaciones Académicas y Científicas - Facultad de Medicina

Ficheros en este ítem:
Fichero Descripción Tamaño Formato   
Stroke volume and cardiac output non invasive monitoring.pdfStroke volume and cardiac output non invasive monitoring6,73 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons