english Icono del idioma   español Icono del idioma  

Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/20.500.12008/55245 Cómo citar
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorPereira, Valeria-
dc.contributor.authorBertalmio, Martín-
dc.contributor.authorPérez De Palleja, Martín-
dc.contributor.authorDuarte, Leticia-
dc.date.accessioned2026-05-28T14:57:40Z-
dc.date.available2026-05-28T14:57:40Z-
dc.date.issued2022-
dc.identifier.citationPereira V, Bertalmio M, Pérez De Palleja M y otros. Incidencia de alteraciones de la frecuencia cardíaca fetal tras la inducción de analgesia del parto neuroaxial. Revista Chilena de Anestesia [en línea]. 2022;51(6):671-677es
dc.identifier.urihttps://hdl.handle.net/20.500.12008/55245-
dc.description.abstractValorar las alteraciones de la variabilidad de la frecuencia cardíaca fetal (FCF) luego de la inducción de analgesia del parto neuroaxial. Ensayo clínico prospectivo analítico de cohortes realizado entre julio de 2020 y julio de 2021, con 59 embarazadas del Centro Hospitalario Pereira Rosell (CHPR) que cumplieron con los criterios de inclusión. Se asignó de forma aleatoria la técnica analgésica (epidural/espinal-epidural). Se monitorizó durante 20 minutos la FCF, presión arterial materna (PA), intensidad de la contracción uterina en Unidades Montevideo (UM) y dolor mediante escala numérica verbal (EVA). Para la FCF en cada uno de los tiempos no se observaron diferencias estadísticamente significativas, ni hubo casos de bradicardia fetal. En la PA y UM no se observaron diferencias estadísticamente significativas. Para la EVA en cada uno de los tiempos no se observaron diferencias estadísticamente significativas, excepto inmediatamente a recibir la analgesia, valor p = 0,046. La CSE no se asoció a mayor riesgo de alteraciones de la FCF. El fentanil intratecal a dosis máxima de 15 mcg es seguro y efectivo para calmar el dolor del trabajo de parto. El alivio del dolor fue similar para los 2 grupos. No se observaron episodios de hipotensión. Ambas técnicas son eficaces para el alivio del dolor con similar perfil de seguridad cuando se usan dosis bajas de fentanil intrarraquídeo.es
dc.description.abstractTo assess changes in fetal heart rate variability (FHR) after induction of neuraxial labor analgesia. Prospec- tive analytical cohort clinical trial conducted between July 2020 and July 2021, with fifty-nine pregnant women from the Pereira Rossell Hospital Center (CHPR) who met the inclusion criteria. Analgesic technique (epidural/spinal epidural) was randomly assigned. FHR, maternal blood pressure (BP), intensity of uterine contraction in Montevideo Units (UM) and pain using a verbal numerical scale (VAS) were monitored for 20 minutes. No statistically significant differences were observed for FHR at each of the times, and there were no cases of fetal bradycardia. In PA and UM, no statistically significant differences were observed. No statistically significant differences were observed for VAS at each of the times, except immediately after receiving analgesia, p value = 0.046. CSE was not associated with a higher risk of FHR alterations. Intrathe- cal fentanyl at a maximum dose of 15 mcg is safe and effective in relieving labor pain. Pain relief was similar for the two groups. No episodes of hypotension were observed. Both techniques are effective for pain relief with a similar safety profile when low doses of intraspinal fentanyl are used.es
dc.format.extent5 p.es
dc.format.mimetypeapplication/pdfes
dc.language.isoeses
dc.publisherSociedad de Anestesiología de Chilees
dc.relation.ispartofRevista Chilena de Anestesia. 2022;51(6):697-701es
dc.rightsLas obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad de la República.(Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014)es
dc.subjectFrecuencia cardíaca fetales
dc.subjectFetal heart ratees
dc.subjectAnalgesia neuroaxiales
dc.subjectNeuroaxial analgesiaes
dc.subjectBradicardiaes
dc.subjectBradycardiaes
dc.subjectVariabilidades
dc.subjectVariabilityes
dc.subject.otherPARTOes
dc.subject.otherANESTESIA EPIDURALes
dc.subject.otherFETOes
dc.subject.otherFRECUENCIA CARDÍACAes
dc.titleIncidencia de alteraciones de la frecuencia cardíaca fetal tras la inducción de analgesia del parto neuroaxiales
dc.title.alternativeIncidence of fetal heart rate abnormalities after neuroaxial labor analgesia inductiones
dc.typeArtículoes
dc.contributor.filiacionPereira Valeria, Universidad de la República (Uruguay). Facultad de Medicina. Departamento de Anestesiología-
dc.contributor.filiacionBertalmio Martín, Universidad de la República (Uruguay). Facultad de Medicina. Departamento de Anestesiología-
dc.contributor.filiacionPérez De Palleja Martín, Universidad de la República (Uruguay). Facultad de Medicina. Departamento de Anestesiología-
dc.contributor.filiacionDuarte Leticia, Universidad de la República (Uruguay). Facultad de Medicina. Departamento de Anestesiología-
dc.rights.licenceLicencia Creative Commons Atribución (CC - By 4.0)es
dc.identifier.doi10.25237/revchilanestv5130091424-
dc.identifier.eissn0719-6792-
Aparece en las colecciones: Publicaciones Académicas y Científicas - Facultad de Medicina

Ficheros en este ítem:
Fichero Descripción Tamaño Formato   
Incidencia de alteraciones de la frecuencia cardíaca fetal.pdfIncidencia de alteraciones de la frecuencia cardíaca fetal2,32 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons