english Icono del idioma   español Icono del idioma  

Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/20.500.12008/54389 Cómo citar
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorVásquez, Joaquín-
dc.contributor.authorFerrando, Federico-
dc.contributor.authorMurguía, Soledad-
dc.contributor.authorIchazo, José-
dc.contributor.authorEscobar, Natalia-
dc.contributor.authorCuesta, Alejandro-
dc.contributor.authorRivara, Álvaro-
dc.contributor.authorFreire, Diego-
dc.date.accessioned2026-04-15T17:08:22Z-
dc.date.available2026-04-15T17:08:22Z-
dc.date.issued2023-
dc.identifier.citationVásquez J, Ferrando F, Murguía S y otros. Remodelado eléctrico reverso en pacientes tratados con terapia de resincronización cardíaca. Revista Argentina de Cardiología [en línea]. 2023;91(1):41-48es
dc.identifier.urihttps://hdl.handle.net/20.500.12008/54389-
dc.description.abstractIntroducción: La terapia de resincronización cardíaca (TRC) se indica en pacientes que habitualmente presentan remodelado cardíaco generado por dilatación y disincronía contráctil. La TRC contribuye al remodelado reverso, relacionado con menor mortalidad y hospitalizaciones por insuficiencia cardíaca (IC). Se han observado además mejoras en la conducción intraventricular, con reducción del tiempo de activación. La cuantificación del remodelado eléctrico reverso se ha subutilizado como parámetro de respuesta, con escasos reportes sobre su asociación con la respuesta clínica-estructural. Objetivo: Analizar el remodelado eléctrico reverso intraventricular como parámetro de respuesta a la TRC. Métodos: Se incluyeron pacientes con más de 6 meses de implante. Se obtuvo un ECG con estimulación desactivada (QRS intrínseco, QRSi, post TRC), y por ecocardiograma transtorácico se definió la fracción de eyección ventricular izquierda (FEVI), el diámetro de fin de diástole del ventrículo izquierdo (DFDVI) y la presencia de insuficiencia mitral. Se clasificó a los pacientes según la respuesta clínica-estructural. El remodelado eléctrico se caracterizó con la comparación de la duración del QRS pre y post TRC y la valoración de los cambios del QRS (ΔQRSi) entre grupos. Resultados: Se incluyeron 23 pacientes. Un 39% presentó disminución >10 mseg del QRSi. Observamos un QRSi de -9,3 ± 20,7 mseg en respondedores, y 11,25 ± 18,9 mseg en no respondedores (p = 0,027), más acentuada en los hiper respondedores (ΔQRSi: -14,44 ± 17,40 mseg, p = 0,026). Las mujeres con QRS ≥150 mseg pre TRC exhibieron disminución significativa del QRSi (p = 0,0195). Conclusiones: El remodelado eléctrico reverso se comprobó en 39% de los pacientes que recibieron TRC. Observamos una relación significativa del QRSi con la respuesta clínica-estructural, mayor en hiper respondedores. Mujeres con QRS ancho pre-TRC exhiben remodelado eléctrico reverso más acentuado. Este es un parámetro de fácil acceso e interpretación durante los controles ambulatorios.es
dc.description.abstractIntroduction: Cardiac resynchronization therapy (CRT) is indicated in patients who often present cardiac remodeling due to dilatation and contractile dyssynchrony. CRT contributes to reverse remodeling which is associated with reduced mortality and heart failure (HF) hospitalizations. Improvements in intraventricular conduction with decreased ventricular activation time have also been observed. The quantification of reverse electrical remodeling has been underused as a parameter of response, and there are few reports on its association with the clinical-structural response. Objective: To analyze intraventricular reverse electrical remodeling as a parameter of response to CRT in living individuals. Methods: We included patients implanted at least 6 months ago. A deactivated stimulation ECG (post-CRT intrinsic QRS) was obtained, and by means of transthoracic echocardiography (TTE), the left ventricular ejection fraction (LVEF), the left ventricular end-diastolic diameter (LVEDD) and the presence of mitral regurgitation were defined. Patients were classified according to their clinical-structural response. Electrical remodeling was characterized by comparing pre- and post-CRT QRS duration and assessing QRS changes (ΔiQRS) between groups. Results: A total of 23 patients were included, 39% of which showed a >10 ms decrease in iQRS. We observed a iQRS of -9.3±20.7 ms in responders, and of 11.25±18.9 ms in non-responders (p=0.027), more marked in hyper-responders (ΔiQRS: -14.44±17.40 ms, p=0.026). Women with pre-CRT QRS ≥150 ms showed a significant decrease in iQRS (p=0.0195). Conclusion: Reverse electrical remodeling was found in 39% of the patients under CRT. We noted a significant relationship between iQRS and clinical-structural response, higher in hyper-responders. Women with wider pre-CRT QRS showed more marked reverse electrical remodeling. This parameter is accessible and easy to read in outpatient visits.es
dc.format.extent8 p.es
dc.format.mimetypeapplication/pdfes
dc.language.isoeses
dc.publisherSociedad Argentina de Cardiologíaes
dc.relation.ispartofRevista Argentina de Cardiología. 2023;91(1):41-48es
dc.rightsLas obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad de la República.(Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014)es
dc.subjectTerapia de resincronización cardíacaes
dc.subjectRespuestaes
dc.subjectRemodelado eléctrico reversoes
dc.subjectCardiac resynchronization therapyes
dc.subjectResponsees
dc.subjectReverse electrical remodelinges
dc.subject.otherINSUFICINCIA CARDÍACAes
dc.subject.otherMORTALDADes
dc.titleRemodelado eléctrico reverso en pacientes tratados con terapia de resincronización cardíacaes
dc.title.alternativeReverse electrical remodeling in patients under cardiac resynchronization therapyes
dc.typeArtículoes
dc.contributor.filiacionVásquez Joaquín, Universidad de la República (Uruguay). Facultad de Medicina, Hospital de Clínicas, Centro Cardiovascular-
dc.contributor.filiacionFerrando Federico, Universidad de la República (Uruguay). Facultad de Medicina, Hospital de Clínicas, Centro Cardiovascular-
dc.contributor.filiacionMurguía Soledad, Universidad de la República (Uruguay). Facultad de Medicina, Hospital de Clínicas, Centro Cardiovascular-
dc.contributor.filiacionIchazo José, Universidad de la República (Uruguay). Facultad de Medicina, Hospital de Clínicas, Centro Cardiovascular-
dc.contributor.filiacionEscobar Natalia, Universidad de la República (Uruguay). Facultad de Medicina, Hospital de Clínicas, Centro Cardiovascular-
dc.contributor.filiacionCuesta Alejandro, Universidad de la República (Uruguay). Facultad de Medicina, Hospital de Clínicas, Centro Cardiovascular-
dc.contributor.filiacionRivara Álvaro, Universidad de la República (Uruguay). Facultad de Medicina, Hospital de Clínicas, Centro Cardiovascular-
dc.contributor.filiacionFreire Diego, Universidad de la República (Uruguay). Facultad de Medicina, Hospital de Clínicas, Centro Cardiovascular-
dc.rights.licenceLicencia Creative Commons Atribución - No Comercial - Compartir Igual (CC - By-NC-SA 4.0)es
dc.identifier.doi10.7775/rac.es.v91.i1.20760-
dc.identifier.eissn1850-3748-
Aparece en las colecciones: Publicaciones Académicas y Científicas - Facultad de Medicina

Ficheros en este ítem:
Fichero Descripción Tamaño Formato   
Remodelado eléctrico reverso en pacientes tratados con terapia de resincronización cardíaca.pdfRemodelado eléctrico reverso en pacientes tratados con terapia de resincronización cardíaca2,29 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons