english Icono del idioma   español Icono del idioma  

Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/20.500.12008/52136 Cómo citar
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorBia, Daniel-
dc.contributor.authorZócalo, Yanina-
dc.contributor.authorSánchez, Ramiro-
dc.contributor.authorTorrado, Juan F.-
dc.contributor.authorLev, Gustavo-
dc.contributor.authorMendiz, Oscar-
dc.contributor.authorPessana, Franco-
dc.contributor.authorRamírez, Agustín-
dc.contributor.authorCabrera-Fischer, Edmundo I.-
dc.date.accessioned2025-10-17T16:58:50Z-
dc.date.available2025-10-17T16:58:50Z-
dc.date.issued2023-
dc.identifier.citationBia D, Zócalo Y, Sánchez R y otros. Brachial Blood Pressure Invasively and Non-Invasively Obtained Using Oscillometry and Applanation Tonometry: Impact of Mean Blood Pressure Equations and Calibration Schemes on Agreement Levels. Journal of Cardiovascular Development and Disease [en línea]. 2023;10(2). 21 p.es
dc.identifier.issn2308-3425-
dc.identifier.urihttps://hdl.handle.net/20.500.12008/52136-
dc.description.abstractThe use of oscillometric methods to determine brachial blood pressure (bBP) can lead to a systematic underestimation of the invasively measured systolic (bSBP) and pulse (bPP) pressure levels, together with a significant overestimation of diastolic pressure (bDBP). Similarly, the agreement between brachial mean blood pressure (bMBP), invasively and non-invasively measured, can be affected by inaccurate estimations/assumptions. Despite several methodologies that can be applied to estimate bMBP non-invasively, there is no consensus on which approach leads to the most accurate estimation. Aims: to evaluate the association and agreement between: (1) non-invasive (oscillometry) and invasive bBP; (2) invasive bMBP, and bMBP (i) measured by oscillometry and (ii) calculated using six different equations; and (3) bSBP and bPP invasively and non-invasively obtained by applanation tonometry and employing different calibration methods. To this end, invasive aortic blood pressure and bBP (catheterization), and non-invasive bBP (oscillometry [Mobil-O-Graph] and brachial artery applanation tonometry [SphygmoCor]) were simultaneously obtained (34 subjects, 193 records). bMBP was calculated using different approaches. Results: (i) the agreement between invasive bBP and their respective non-invasive measurements (oscillometry) showed dependence on bBP levels (proportional error); (ii) among the different approaches used to obtain bMBP, the equation that includes a form factor equal to 33% (bMBP = bDBP + bPP/3) showed the best association with the invasive bMBP; (iii) the best approach to estimate invasive bSBP and bPP from tonometry recordings is based on the calibration scheme that employs oscillometric bMBP. On the contrary, the worst association between invasive and applanation tonometry-derived bBP levels was observed when the brachial pulse waveform was calibrated to bMBP quantified as bMBP = bDBP + bPP/3. Our study strongly emphasizes the need for methodological transparency and consensus for non-invasive bMBP assessment.es
dc.format.extent21 p.es
dc.format.mimetypeapplication/pdfes
dc.language.isoenes
dc.relation.ispartofJournal of Cardiovascular Development and Disease. 2023;10(2)es
dc.rightsLas obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad de la República.(Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014)es
dc.subjectAortic pressurees
dc.subjectApplanation tonometryes
dc.subjectBrachial blood pressurees
dc.subjectCalibration procedurees
dc.subjectInvasive recordses
dc.subjectMean blood pressurees
dc.subjectNon-invasive recordses
dc.subjectOscillometryes
dc.subjectPulse waveformes
dc.subject.otherPRESIÓN ARTERIALes
dc.subject.otherPRESIÓN SANGUÍNEAes
dc.subject.otherOSCILOMETRÍAes
dc.subject.otherCALIBRACIÓNes
dc.titleBrachial Blood Pressure Invasively and Non-Invasively Obtained Using Oscillometry and Applanation Tonometry: Impact of Mean Blood Pressure Equations and Calibration Schemes on Agreement Levelses
dc.typeArtículoes
dc.contributor.filiacionBia Daniel, Universidad de la República (Uruguay). Facultad de Medicina-
dc.contributor.filiacionZócalo Yanina, Universidad de la República (Uruguay). Facultad de Medicina-
dc.contributor.filiacionSánchez Ramiro, Fundación Favaloro (Argentina). Hospital Universitario-
dc.contributor.filiacionTorrado Juan F., Universidad de la República (Uruguay). Facultad de Medicina-
dc.contributor.filiacionLev Gustavo, Fundación Favaloro (Argentina). Hospital Universitario-
dc.contributor.filiacionMendiz Oscar, Fundación Favaloro (Argentina). Hospital Universitario-
dc.contributor.filiacionPessana Franco, Universidad Favaloro (Argentina). Facultad de Ingeniería y Ciencias Exactas-
dc.contributor.filiacionRamírez Agustín, Instituto de Medicina Traslacional, Trasplante y Bioingeniería (Argentina)-
dc.contributor.filiacionCabrera-Fischer Edmundo I., Instituto de Medicina Traslacional, Trasplante y Bioingeniería (Argentina)-
dc.rights.licenceLicencia Creative Commons Atribución (CC - By 4.0)es
dc.identifier.doi10.3390/jcdd10020045-
Aparece en las colecciones: Publicaciones Académicas y Científicas - Facultad de Medicina

Ficheros en este ítem:
Fichero Descripción Tamaño Formato   
Brachial Blood Pressure Invasively and Non-Invasively Obtained Using Oscillometry and Applanation Tonometry.pdfBrachial Blood Pressure31,41 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons