Por favor, use este identificador para citar o enlazar este ítem:
https://hdl.handle.net/20.500.12008/43532
Cómo citar
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Simini, Franco | es |
dc.contributor.author | Santos, Darío | es |
dc.contributor.author | Artigas, José | es |
dc.contributor.author | Gigirey, Verónica | es |
dc.contributor.author | Dibarboure, Luis | es |
dc.contributor.author | Francescoli, Luis | es |
dc.date.accessioned | 2024-04-16T16:21:15Z | - |
dc.date.available | 2024-04-16T16:21:15Z | - |
dc.date.issued | 2017 | es |
dc.date.submitted | 20240416 | es |
dc.identifier.citation | Simini, F, Santos, D, Artigas, J, Gigirey, V, Dibarboure, L, Francescoli L. "Measurement of knee articulation laxity by videofluoroscopy image analysis: CINARTRO". Medical Imaging Radiology, v.5, no.4. 2017. http://dx.doi.org/10.7243/2054-1945-5-4 | es |
dc.identifier.issn | 2054-1945 | es |
dc.identifier.uri | https://hdl.handle.net/20.500.12008/43532 | - |
dc.description.abstract | Several methods are used to evaluate knee articulation during movement, such as the Tibio Femoral Contact Point migration or the Instantaneous Centre of Rotation displacement and even the Moment Arm variations during extension. Such evaluation is important in case of Anterior Cruciate Ligament reconstruction or Total Knee Replacement, but unfortunately, it is only available in research settings. We have devised a novel clinical methodology based on serial images of knee movement videof luoroscopy, which are interactively analysed to allow automatic determination of kinematics parameters. The method, called CINARTRO, compares values with the contralateral knee and produces a standard Clinical Document Architecture file ready for Electronic Medical Record systems. To correct the “pin cushion” effect of X ray intensifiers, a 10 mm apart lead spheres phantom was developed. To validate the interactive selection of anatomical points, cadaver limbs were marked with lead markers and compared with points marked on the blind image. Anterior Cruciate Ligament (injured and reconstructed) and contralateral Moment Arms averages of 53mm, 39mm and 43mm respectively were found. Similarly the Total Knee Replacement patient`s Moment Arm was reduced to 33mm. These findings justify the use of our methodology to help clinicians during rehabilitation follow-up. Keywords : : Knee Kinematics, Tibio Femoral Contact Point, Quadriceps Moment Arm, Videofluoroscopy, CINARTRO | es |
dc.language | en | es |
dc.publisher | HOAJ | es |
dc.relation.ispartof | Medical Imaging and Radiology, v. 5, article 4, 2017 | es |
dc.rights | Las obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad De La República. (Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014) | es |
dc.subject | Knee Kinematics | es |
dc.subject | Tibio femoral contact point | es |
dc.subject | Quadriceps moment arm | es |
dc.subject | CINARTRO | es |
dc.subject.other | Sistemas y Control | es |
dc.title | Measurement of knee articulation laxity by videofluoroscopy image analysis : CINARTRO | es |
dc.type | Artículo | es |
dc.rights.licence | Licencia Creative Commons Atribución – No Comercial (CC – By-NC) | es |
dc.identifier.doi | doi: 10.7243/2054-1945-5-4 | es |
Aparece en las colecciones: | Publicaciones académicas y científicas - Instituto de Ingeniería Eléctrica |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | ||
---|---|---|---|---|---|
SSAGDF17a.pdf | 597,73 kB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons