dc.identifier.citation | Simini, F, Díaz, S, Tobal, D, Peirano, F, Sitrin, M, Arrua, E, Noboa, O. "NEFROVOL Organ reconstruction method from US scans for 3D printing to better patient- physician relationship : volume measurement accuracy" 2017 | es |
dc.identifier.uri | https://hdl.handle.net/20.500.12008/43527 | - |
dc.description.abstract | For vaguely symmetrical organs, volume measurement is based on pseudo-sphere calculations taking Ultrasound (US) scan “diameters”. Some medical conditions nevertheless, such as Poly-cystic Kidney Disease (PKD), greatly deform the organ (Kidney in this case), and therefore only finite elements approximations can render the volume and calculate its value. Contrast media and ionizing radiations (X Rays) of CT scans, are not always suitable due to toxicity and radiation effects. We have developed NEFROVOL, a low cost, non-invasive solution to estimate volume from parallel US images to generate 3D organ models. [1]. The model is 3D printed to be used during the visit with the physician, either full scale or reduced. The volume estimation method is validated here | es |
dc.language | en | es |
dc.rights | Las obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad De La República. (Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014) | es |
dc.subject.other | Sistemas y Control | es |
dc.title | NEFROVOL Organ reconstruction method from US scans for 3D printing to better patient- physician relationship : volume measurement accuracy | es |
dc.type | Otro | es |
dc.rights.licence | Licencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0) | es |
Aparece en las colecciones: | Publicaciones académicas y científicas - Instituto de Ingeniería Eléctrica |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | ||
---|---|---|---|---|---|
SDTPSAN17.pdf | 71,48 kB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons