Por favor, use este identificador para citar o enlazar este ítem:
https://hdl.handle.net/20.500.12008/42741
Cómo citar
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Simini, Franco | es |
dc.contributor.author | Santos, Darío | es |
dc.contributor.author | Francescoli, Luis | es |
dc.date.accessioned | 2024-02-26T19:52:52Z | - |
dc.date.available | 2024-02-26T19:52:52Z | - |
dc.date.issued | 2016 | es |
dc.date.submitted | 20240223 | es |
dc.identifier.citation | Simini, F, Santos, D, Francescoli. L. "Videofluoroscopy instrument to identify the tibiofemoral contact point migration for anterior cruciate ligament reconstruction follow-up : CINARTRO" Journal of Physics: Conference Series, v. 705, 2016. doi:10.1088/1742-6596/705/1/012056 | es |
dc.identifier.uri | https://hdl.handle.net/20.500.12008/42741 | - |
dc.description | 20mo. Congreso Argentino de Bioingeniería y 9as. Jornadas de Ingeniería Clínica, San Nicolás de los Arroyos, Argentina, 28–30 October 2015 | es |
dc.description.abstract | We measure the Tibiofemoral contact point migration to offer clinicians a tool to evaluate Anterior Cruciate Ligament reconstruction. The design of the tool includes a C arm with fluoroscopy, image acquisition and processing system, interactive software and report generation for the clinical record. The procedure samples 30 images from the videofluoroscopy describing 2 seconds movements of hanging-to-full-extension of the knee articulation. A geometrical routine implemented in the original equipment (CINARTRO) helps capture tibial plateau and femoral condile profile by interaction with the user. The tightness or looseness of the knee is expressed by the migration given in terms of movement of the femur along the tibial plateau, as a percentage. We automatically create clinical reports in standard Clinical Document Architecture or CDA format. A special phantom was developed to correct the “pin cushion effect” in Rx images. Five cases of broken ACL patients were measured giving meaningful results for clinical follow up. Tibiofemoral contact point migration was measured as 60% of the tibial plateau, with standard deviation of 6% for healthy knees, 4% when injured and 1% after reconstruction. | es |
dc.language | en | es |
dc.publisher | IOP Publishing | es |
dc.relation.ispartof | Journal of Physics: Conference Series, v. 705, 2016 | es |
dc.rights | Las obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad De La República. (Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014) | es |
dc.subject.other | Sistemas y Control | es |
dc.title | Videofluoroscopy instrument to identify the tibiofemoral contact point migration for anterior cruciate ligament reconstruction follow-up : CINARTRO | es |
dc.type | Ponencia | es |
dc.rights.licence | Licencia Creative Commons Atribución (CC - By 4.0) | es |
dc.identifier.doi | 10.1088/1742-6596/705/1/012056 | es |
Aparece en las colecciones: | Publicaciones académicas y científicas - Instituto de Ingeniería Eléctrica |