Por favor, use este identificador para citar o enlazar este ítem:
https://hdl.handle.net/20.500.12008/42740
Cómo citar
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Schandy, Javier | es |
dc.contributor.author | Oreggioni, Julián | es |
dc.contributor.author | Steinfeld, Leonardo | es |
dc.date.accessioned | 2024-02-26T19:52:52Z | - |
dc.date.available | 2024-02-26T19:52:52Z | - |
dc.date.issued | 2016 | es |
dc.date.submitted | 20240223 | es |
dc.identifier.citation | Schandy, J. Oreggioni, J, Steinfeld, L. "DC-DC switching converter as on-field self energy meter" Proceedings of the IEEE 7th Latin American Symposium on Circuits and Systems (LASCAS), Florianopolis, Brasil, 28 feb.-2 mar., 2016, pp. 139-142, doi: 10.1109/LASCAS.2016.7451029. | es |
dc.identifier.uri | https://hdl.handle.net/20.500.12008/42740 | - |
dc.description | Trabajo presentado en 7th Latin American Symposium on Circuits and Systems (LASCAS), Florianopolis, Brasil, 28 feb. - 2 mar., 2016 | es |
dc.description.abstract | A DC-DC switching converter, originally included to reduce the power consumption of a Wireless Sensor Networks (WSN) node, has been proposed as the core of an on-field self-energy meter. In this paper we present a method and circuit that improves the electronics proposed by previous work by conditioning the signal from the switching converter that is connected to the microcontroller's counter. A software module that allows a WSN node to measure its own charge and current consumption was also implemented. The proposed method allows to measure the current consumption in a wide range, from 0 to 30mA, is highly linear and is ultra-low-power (the maximum current consumption is 8µA). Finally, we present a case study in which the proposed method is used to power profile a WSN node. Results show that a time-based estimation (Energest) overestimates the Clear Channel Assessment consumption for more than 10%. | es |
dc.language | en | es |
dc.rights | Las obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad De La República. (Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014) | es |
dc.subject | Wireless sensor networks | es |
dc.subject | Low-power design | es |
dc.subject | DC-DC converter | es |
dc.subject | Energy measurement | es |
dc.subject | Contiki OS | es |
dc.subject.other | Electrónica | es |
dc.title | DC-DC switching converter as on-field self energy meter | es |
dc.type | Ponencia | es |
dc.rights.licence | Licencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0) | es |
udelar.academic.department | Electrónica | - |
udelar.investigation.group | Microelectrónica | - |
Aparece en las colecciones: | Publicaciones académicas y científicas - Instituto de Ingeniería Eléctrica |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | ||
---|---|---|---|---|---|
SOS16.pdf | 520,07 kB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons