dc.contributor.author | Decia, Ignacio | es |
dc.contributor.author | Farías, Agustín | es |
dc.contributor.author | Szerman, Deborah | es |
dc.contributor.author | Grundel, Lucía | es |
dc.contributor.author | Briatore, Diego | es |
dc.contributor.author | Piñeyrúa, María | es |
dc.contributor.author | Villar, Álvaro | es |
dc.contributor.author | Simini, Franco | es |
dc.date.accessioned | 2024-02-26T19:52:44Z | - |
dc.date.available | 2024-02-26T19:52:44Z | - |
dc.date.issued | 2016 | es |
dc.date.submitted | 20240223 | es |
dc.identifier.citation | Decia, I, Farias, A, Szerman, D, Grundel, L, Briatore, D, Pineyrua, M, Villar, A, Simini1, F. "CAMACUA: low cost real time risk alert and location system for healthcare environments. 7mo. Latin American Congress on Biomedical Engineering CLAIB 2016, Bucaramanga, Santander, Colombia, 26-28 oct., 2016. IFMBE Proceedings, vol 60. Springer, https://doi.org/10.1007/978-981-10-4086-3_23 | es |
dc.identifier.uri | https://hdl.handle.net/20.500.12008/42710 | - |
dc.description.abstract | Medication error and other risky situations can lead to serious patient injuries or discomfort. We have designed a real time risk alert and location system to increase patient safety and to reduce medication administration errors. CAMACUA is based on barcode and passive RFID technology for real time location. First field test results show that 100% of patients, visitors and hospital assets are correctly located within hospital rooms or transitions > 1m. When closer than 1m from room entrance, 30% of objects need additional data to determine their location. Keywords : Medication error, Patient safety, Radio frequency identification, Real time location system. | es |
dc.language | en | es |
dc.relation.ispartof | 7mo, Latin American Congress on Biomedical Engineering CLAIB 2016, Bucaramanga, Colombiam, 26 – 28 oct., 2016 | es |
dc.rights | Las obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad De La República. (Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014) | es |
dc.subject | Medication error | es |
dc.subject | Patient safety | es |
dc.subject | Radio frequency identification | es |
dc.subject | Real time location system | es |
dc.subject.other | Sistemas y Control | es |
dc.title | CAMACUA : Low cost real time risk alert and location system for healthcare environments | es |
dc.type | Ponencia | es |
dc.rights.licence | Licencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0) | es |
Aparece en las colecciones: | Publicaciones académicas y científicas - Instituto de Ingeniería Eléctrica |