Por favor, use este identificador para citar o enlazar este ítem:
https://hdl.handle.net/20.500.12008/41130
Cómo citar
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Subramanian, Sriram | es |
dc.contributor.author | Sapiro, Guillermo | es |
dc.contributor.author | Lecumberry, Federico | es |
dc.contributor.author | Bartesaghi, Alberto | es |
dc.date.accessioned | 2023-11-14T17:04:26Z | - |
dc.date.available | 2023-11-14T17:04:26Z | - |
dc.date.issued | 2012 | es |
dc.date.submitted | 20231114 | es |
dc.identifier.citation | Subramanian, S, Sapiro, G, Lecumberry, F, Bartesaghi, A. “Protein secondary structure determination by constrained single-particle cryo-electron tomography”. Structure, 2012, v. 20, no. 12. https://doi.org/10.1016/j.str.2012.10.016 | es |
dc.identifier.uri | https://hdl.handle.net/20.500.12008/41130 | - |
dc.description.abstract | Cryo-electron microscopy (cryo-EM) is a powerful technique for 3D structure determination of protein complexes by averaging information from individual molecular images. The resolutions that can be achieved with single-particle cryo-EM are frequently limited by inaccuracies in assigning molecular orientations based solely on 2D projection images. Tomographic data collection schemes, however, provide powerful constraints that can be used to more accurately determine molecular orientations necessary for 3D reconstruction. Here, we propose constrained single-particle tomography as a general strategy for 3D structure determination in cryo-EM. A key component of our approach is the effective use of images recorded in tilt series to extract high-resolution information and correct for the contrast transfer function. By incorporating geometric constraints into the refinement to improve orientational accuracy of images, we reduce model bias and overrefinement artifacts and demonstrate that protein structures can be determined at resolutions of 8 A° starting from low-dose tomographic tilt series. | es |
dc.language | en | es |
dc.publisher | Elsevier | es |
dc.relation.ispartof | Structure, 2012, v. 20, no. 12 | es |
dc.rights | Las obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad De La República. (Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014) | es |
dc.subject.other | Procesamiento de Señales | es |
dc.title | Protein secondary structure determination by constrained single-particle cryo-electron tomography | es |
dc.type | Artículo | es |
dc.rights.licence | Licencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0) | es |
dc.identifier.doi | https://doi.org/10.1016/j.str.2012.10.016 | es |
udelar.academic.department | Procesamiento de Señales | - |
udelar.investigation.group | Tratamiento de Imágenes | - |
Aparece en las colecciones: | Publicaciones académicas y científicas - Instituto de Ingeniería Eléctrica |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | ||
---|---|---|---|---|---|
blss12.pdf | 2,1 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons