english Icono del idioma   español Icono del idioma  

Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/20.500.12008/31430 Cómo citar
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorJuanicó, Luis Eduardo-
dc.contributor.authorBove, Italo-
dc.coverage.spatialBariloche, Argentina.es
dc.coverage.spatialMontevideo, Uruguay.es
dc.coverage.spatialSantiago de Chile, Chile.es
dc.date.accessioned2022-05-04T19:28:39Z-
dc.date.available2022-05-04T19:28:39Z-
dc.date.issued2022-
dc.identifier.citationJuanicó, L.E. y Bove, I. "Evaluación energética y económica de calefacción de hogares por bomba de calor en Bariloche, Montevideo y Santiago" Revista Técnica de la Facultad de Ingeniería. Universidad de Zulia [en línea] vol. 45, Nº 1, Enero - Abril, 2022, pp. 58-68.es
dc.identifier.urihttps://hdl.handle.net/20.500.12008/31430-
dc.description.abstractEl cambio climático obliga a mejorar la eficiencia del consumo de energía. En este trabajo se desarrolla una metodología de evaluación energética y económica de las ventajas de sustituir sistemas de calefacción tradicionales de gas natural, GLP, o electricidad, por una moderna bomba de calor (inverter). Al ser su eficiencia función de la diferencia de temperaturas entre el ambiente exterior y el interior, la eficiencia varía según la ubicación de la ciudad. De esta manera, se estudia su rendimiento en Bariloche, Santiago de Chile y Montevideo (temperatura media anual de 8,3; 14,6 y 16,3 °C, respectivamente), empleando los siguientes sistemas: 1) aire-aire, instalando varios equipos Split; y 2) aire-agua, instalando una bomba de calor que brinde calefacción por radiadores de agua. Esta metodología permite dimensionar estos sistemas y calcular el ahorro anual, ejemplificándose para una vivienda social de 50 m2. En todos los casos estudiados se alcanzaron reducciones de los consumos y ahorros de moderados a notables (y períodos de repago de la inversión menores a dos años), excepto contra el gas natural en Bariloche y Montevideo. Se discute también cómo su inversión moderada puede constituir una primera solución asequible, frente a la costosa rehabilitación térmica, a fin de obtener viviendas más sustentables.es
dc.description.abstractClimate change forces to improve the efficiency of energy consumption. This work develops a methodology for energy and economic assessment related to replacing a standard household heating system fueled by natural gas, LPG, or conventional electric heaters, with a modern heat pump (inverter). As its efficiency is related to the temperature difference between the outdoor and indoor environments, the efficiency varies depending on the location of the city. Thus, the performance is studied in Bariloche, Santiago de Chile, and Montevideo (Average annual temperature of 8.3, 14.6 and 16.3 °C, respectively), using the following systems: 1) air-air, installing several Split devices; and 2) air-water, installing a heat pump that provides heating by water radiators. This methodology allows sizing these systems and calculating annual savings, exemplified for a 50 m2 social housing. In all the cases studied, moderate to notable reductions in consumption and savings were achieved (and investment payback periods of less than two years), except for natural gas in Bariloche and Montevideo. It is also discussed how their moderated investment can be an affordable first solution, as opposed to the expensive thermal rehabilitation, for obtaining more sustainable housing.es
dc.format.extent10 p.es
dc.format.mimetypeapplication/pdfes
dc.language.isoeses
dc.publisherUniversidad del Zuliaes
dc.relation.ispartofRevista Técnica de la Facultad de Ingeniería de la Universidad del Zulia, vol. 45, Nº 1, Enero - Abril, 2022, pp. 58-68.es
dc.rightsLas obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad de la República.(Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014)es
dc.subjectCalefacción por bomba de calores
dc.subjectBomba de calor Split aire/airees
dc.subjectBomba de calor aire/aguaes
dc.subjectCalefactores de gas hogareños de tiro balanceadoes
dc.subjectCalderas de gases
dc.titleEvaluación energética y económica de calefacción de hogares por bomba de calor en Bariloche, Montevideo y Santiago.es
dc.typeArtículoes
dc.contributor.filiacionJuanicó Luis Eduardo , Instituto Andino Patagónico de Tecnologías Biológicas y Geoambientales, Argentina-
dc.contributor.filiacionBove Italo, Universidad de la República (Uruguay). Laboratorio de Energía Solar. Facultad de Ingeniería-
dc.rights.licenceLicencia Creative Commons Atribución - No Comercial - Compartir Igual (CC - By-NC-SA 4.0)es
dc.identifier.doi10.22209/rt.v45n1a06-
Aparece en las colecciones: Publicaciones académicas y científicas - Laboratorio de Energía Solar (LES)

Ficheros en este ítem:
Fichero Descripción Tamaño Formato   
JB22.pdfArtículo3,71 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons