english Icono del idioma   español Icono del idioma  

Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/20.500.12008/30075 Cómo citar
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorGehrke, S.A.-
dc.contributor.authorPrados-Frutos, J.C.-
dc.contributor.authorPrados-Privado, M.-
dc.contributor.authorCalvo-Guirado, J.L.-
dc.contributor.authorAramburú Júnior, J.-
dc.contributor.authorPérez-Díaz, Leticia-
dc.contributor.authorMazón, P.-
dc.contributor.authorAragoneses, J.M.-
dc.contributor.authorDe Aza, P.N.-
dc.date.accessioned2021-11-08T14:52:38Z-
dc.date.available2021-11-08T14:52:38Z-
dc.date.issued2019-
dc.identifier.citationGehrke, S, Prados-Frutos, J, Prados-Privado, M, [y otros] "Biomechanical and histological analysis of titanium (machined and treated surface) versus zirconia implant materials: an in vivo animal study". Materials. [en línea] 2019, 12(6): 856. 13 h. DOI: 10.3390/ma12060856es
dc.identifier.issn1996-1944-
dc.identifier.urihttps://hdl.handle.net/20.500.12008/30075-
dc.descriptionThis article belongs to the Special Issue Clinical Implants and the Biocompatibility of Biodegradable Biomaterialsen
dc.description.abstractObjectives: The aim of this study was to perform an in vivo histological comparative evaluation of bone formation around titanium (machined and treated surface) and zirconia implants. For the present study were used 50 commercially pure titanium implants grade IV, being that 25 implants with a machined surface (TiM group), 25 implants with a treated surface (TiT group) and, 25 implants were manufactured in pure zirconia (Zr group). The implants (n = 20 per group) were installed in the tibia of 10 rabbits. The implants distribution was randomized (n = 3 implants per tibia). Five implants of each group were analyzed by scanning electron microscopy and an optical laser profilometer for surface roughness characterization. Six weeks after the implantation, 10 implants for each group were removed in counter-torque for analysis of maximum torque value. The remaining samples were processed, included in historesin and cut to obtain non-decalcified slides for histomorphological analyses and histomorphometric measurement of the percentage of bone-implant contact (BIC%). Comparisons were made between the groups using a 5% level of significance (p < 0.05) to assess statistical differences. The results of removal torque values (mean ± standard deviation) showed for the TiM group 15.9 ± 4.18 N cm, for TiT group 27.9 ± 5.15 N cm and for Zr group 11.5 ± 2.92 N cm, with significant statistical difference between the groups (p < 0.0001). However, the BIC% presented similar values for all groups (35.4 ± 4.54 for TiM group, 37.8 ± 4.84 for TiT group and 34.0 ± 6.82 for Zr group), with no statistical differences (p = 0.2171). Within the limitations of the present study, the findings suggest that the quality of the new bone tissue formed around the titanium implants present a superior density (maturation) in comparison to the zirconia implants.en
dc.format.extent13 h.es
dc.format.mimetypeapplication/pdfes
dc.language.isoenes
dc.publisherMDPIes
dc.relation.ispartofMaterials, 2019, 12(6): 856es
dc.rightsLas obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad de la República.(Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014)es
dc.subjectOsseointegrationen
dc.subjectBone healingen
dc.subjectBone qualityen
dc.subjectZirconia implantsen
dc.subjectTitanium implantsen
dc.titleBiomechanical and histological analysis of titanium (machined and treated surface) versus zirconia implant materials: an in vivo animal studyen
dc.typeArtículoes
dc.contributor.filiacionGehrke S.A.-
dc.contributor.filiacionPrados-Frutos J.C.-
dc.contributor.filiacionPrados-Privado M.-
dc.contributor.filiacionCalvo-Guirado J.L.-
dc.contributor.filiacionAramburú Júnior J.-
dc.contributor.filiacionPérez-Díaz Leticia, Universidad de la República (Uruguay). Facultad de Ciencias. Instituto de Química Biológica.-
dc.contributor.filiacionMazón P.-
dc.contributor.filiacionAragoneses J.M.-
dc.contributor.filiacionDe Aza P.N.-
dc.rights.licenceLicencia Creative Commons Atribución (CC - By 4.0)es
dc.identifier.doi10.3390/ma12060856-
Aparece en las colecciones: Publicaciones académicas y científicas - Facultad de Ciencias

Ficheros en este ítem:
Fichero Descripción Tamaño Formato   
10.3390ma12060856.pdf4,14 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons