Título: Behaviour of power-factor meters under non-sinusoidal current and voltage
Autor: Slomovitz, Daniel
Tipo: Artículo
Fecha de publicación: 1991
Resumen: Different types of analogue and digital power-factor meters used for low frequencies are studied. Their errors are calculated when the current or voltage waveform is distorted. It is shown that large errors appear under these working conditions. A new measuring instrument is proposed. It has very small errors, even under highly distorted waveforms, having low-pass filters at the inputs to prevent errors generated by high frequency harmonics.
Editorial: Francis and Taylor
EN: International Journal of Electronics, 1991, v.70, no.4
Citación: Slomovitz, Daniel. Behaviour of power-factor meters under non-sinusoidal current and voltage [en línea] International Journal of Electronics, 1991, v.70, no.4
Aparece en las colecciones: Publicaciones académicas y científicas - Instituto de Ingeniería Eléctrica