Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/20.500.12008/31258

Título:

Ventilación y COVID-19

Otros títulos:

Coordinador:

Director:

Compilador:

Autor:

Gómez, Ana Paula
Vignolo, Andrés
Wener, Natalia

Tutor:

Draper, Martín
Mendina, Mariana

Tipo de documento:

Tesis de grado

Editor:

Palabras clave:

Ventilación
IAQ
Escuelas
Riesgo de contagio
Modelos de caja
Wells-Riley
Confort térmico
SARS-CoV-2
COVID-19"

Descriptores:

Año de publicación:

2022

Contenido:

Resumen:

La pandemia de COVID-19 ha destacado la importancia de la Calidad de Aire Interior (IAQ), particularmente debido a la posibilidad de contagio por vía aérea de larga distancia. En consecuencia, estimar la tasa de ventilación y el riesgo de contagio se ha convertido en una tarea de primordial importancia. El presente proyecto estudia la IAQ en una escuela pública de Montevideo (Uruguay) con ventilación natural, basándose en una campaña de medidas llevada a cabo entre julio y diciembre de 2021. Se midieron las concentraciones de material particulado (PM) y dióxido de carbono (CO2) dentro de un salón de clase y fuera de la escuela, así como algunas variables meteorológicas. Asimismo, se estimaron la tasa de ventilación y el riesgo de contagio por vía aérea de larga distancia mediante el uso de modelos de caja con mezcla perfecta y de las medidas de CO2. En particular, se utilizaron modelos de Wells-Riley para la estimación del riesgo de contagio. Por otra parte, se analizó la relación entre el confort térmico de los ocupantes y la tasa de ventilación mediante la implementación de un modelo BEM (Building Energy Modeling) en EnergyPlus y se propuso un sistema de HVAC centralizado para mejorar el confort térmico y la IAQ durante la temporada de calefacción.
The importance of Indoor Air Quality (IAQ) has been highlighted by the COVID-19 pandemic, particularly due to the possibility of long-distance airborne contagion. Consequently, assessment of ventilation rates and estimation of contagion risk has become a matter of the utmost importance. This project focuses on the assessment of IAQ at a public school building in Montevideo (Uruguay) with natural ventilation, based on a measurement campaign conducted between July and December of 2021. Both Particulate Matter (PM) and carbon dioxide (CO2) concentrations were measured inside a classroom and outside the school, as well as some meteorological variables. Furthermore, ventilation rates and long-distance contagion risk were assessed through the use of fully-mixed box models and CO2 measurements. In particular, Wells-Riley models were used for risk assessment. Additionally, the interaction between occupants’ thermal comfort and ventilation rates was explored by implementing a BEM (Building Energy Modeling) model in EnergyPlus, and a central HVAC system was proposed in order to improve thermal comfort and IAQ during the heating season.

Descripción:

Editorial:

Udelar.FI.

EN:

Financiadores:

Citación:

Gómez, A., Vignolo, A. y Wener, N. Ventilación y COVID-19 [en línea] Tesis de grado. Montevideo : Udelar. FI. IIMPI, 2022

Citación:

metadata.cc.license.name:

Documento del Gobiberno:

URI:

https://hdl.handle.net/20.500.12008/31258

ISBN:

e-ISBN:

ISSN:

ISMN:

Otros identificadores:

Título Obtenido:

Ingeniero Industrial Mecánico

Facultad o Servicio que otorga el Título:

Universidad de la República (Uruguay). Facultad de Ingeniería

Licencia:

Licencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0)

Cobertura geográfica:

Cobertura temporal:

metadata.dc.relation.IsVersionOf:

Clasificación:

Es versión de:

FicherosDescripciónTamañoFormato
GVW22.pdf Tesis de grado 102.59 MB Adobe PDF