Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/20.500.12008/50415
MetadatoEtiquetaValorIdioma
dc.contributor.author Autor Maccio, Sabrina Antonella-
dc.contributor.author Autor Alaniz, Ruben Darío-
dc.contributor.author Autor Pierini, Gastón Darío-
dc.contributor.author Autor Zon, María Alicia-
dc.contributor.author Autor Arévalo, Fernando Javier-
dc.contributor.author Autor Fernández, Héctor-
dc.contributor.author Autor Goicoechea, Héctor Casimiro-
dc.contributor.author Autor Robledo, Sebastian Noel-
dc.contributor.author Autor Alcaraz, Mirta Raquel-
dc.contributor.filiacion Filiación Maccio Sabrina Antonella, Universidad de la República (Uruguay). Facultad de Ciencias. Centro de Investigaciones Nucleares.-
dc.contributor.filiacion Filiación Alaniz Ruben Darío-
dc.contributor.filiacion Filiación Pierini Gastón Darío-
dc.contributor.filiacion Filiación Zon María Alicia-
dc.contributor.filiacion Filiación Arévalo Fernando Javier-
dc.contributor.filiacion Filiación Fernández Héctor-
dc.contributor.filiacion Filiación Goicoechea Héctor Casimiro-
dc.contributor.filiacion Filiación Robledo Sebastian Noel-
dc.contributor.filiacion Filiación Alcaraz Mirta Raquel-
dc.date.accessioned Fecha ingreso 2025-06-26T17:22:44Z-
dc.date.available Fecha disponible 2025-06-26T17:22:44Z-
dc.date.issued Año de publicación 2024-
dc.description Descripción Material suplementario en: https://www.mdpi.com/article/10.3390/chemosensors12090197/s1es
dc.description.abstract Resumen A novel, simple, rapid, and non-expensive analytical method based on square wave voltammogram at Pt microelectrode coupled with partial least square multivariate calibration was used for the simultaneous quantitation of thymol (THY) and carvacrol (CAR) in thyme and oregano essential oils. Results demonstrated that the multivariate calibration method successfully exploited the first-order advantage, rendering highly satisfactory quantitative figures (average recoveries not statistically different than 100%). Moreover, the results agree well with those obtained from the official analytical method. Last, the method’s environmental sustainability was asserted using the AGREE metric, highlighting its eco-friendly nature. More importantly, the proposed analytical procedure does not require previous sample preparation or electrode surface modification. The results underscore the suitability of the method for determining THY and CAR in essential oils at low concentrations (LOD ~ 7.6 µM) with REP% below 5.6%, meeting the requirements of the green analytical chemistry.es
dc.format.extent Extensión 15 hes
dc.format.mimetype Formato application/pdfes
dc.identifier.citation Citación Maccio, S, Alaniz, R, Pierini, G [y otros autores]. "A straightforward electrochemical approach for the simultaneous determination of thymol and carvacrol in essential oils". Chemosensors. [en línea] 2024, 12(9): 197. 15 h. DOI: 10.3390/chemosensors12090197es
dc.identifier.issn ISSN 2227-9040-
dc.identifier.issn ISSN 10.3390/chemosensors12090197-
dc.identifier.uri URI https://hdl.handle.net/20.500.12008/50415-
dc.language.iso Idioma enes
dc.publisher Editorial MDPIes
dc.relation.ispartof EN Chemosensors, 2024, 12(9): 197.es
dc.rights Derechos Las obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad de la República.(Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014)es
dc.rights.licence Licencia Licencia Creative Commons Atribución (CC - By 4.0)es
dc.subject Palabras clave Thymoles
dc.subject Palabras clave Carvacroles
dc.subject Palabras clave Pt-microelectrodees
dc.subject Palabras clave Essential oilses
dc.subject Palabras clave Partial least squareses
dc.title Título A straightforward electrochemical approach for the simultaneous determination of thymol and carvacrol in essential oilses
dc.type Tipo de documento Artículoes
FicherosDescripciónTamañoFormato
10.3390-chemosensors12090197.pdf — 1.44 MB Adobe PDF