Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/20.500.12008/52099
MetadatoEtiquetaValorIdioma
dc.contributor.author Autor Bia, Daniel-
dc.contributor.author Autor Zócalo, Yanina-
dc.contributor.author Autor Sánchez, Ramiro-
dc.contributor.author Autor Lev, Gustavo-
dc.contributor.author Autor Mendiz, Oscar-
dc.contributor.author Autor Pessana, Franco-
dc.contributor.author Autor Ramírez, Agustín-
dc.contributor.author Autor Cabrera-Fischer, Edmundo I.-
dc.contributor.filiacion Filiación Bia Daniel, Universidad de la República (Uruguay). Facultad de Medicina-
dc.contributor.filiacion Filiación Zócalo Yanina, Universidad de la República (Uruguay). Facultad de Medicina-
dc.contributor.filiacion Filiación Sánchez Ramiro, Fundación Favaloro (Argentina). Hospital Universitario-
dc.contributor.filiacion Filiación Lev Gustavo, Fundación Favaloro (Argentina). Hospital Universitario-
dc.contributor.filiacion Filiación Mendiz Oscar, Fundación Favaloro (Argentina). Hospital Universitario-
dc.contributor.filiacion Filiación Pessana Franco, Universidad Favaloro (Argentina). Facultad de Ingeniería y Ciencias Exactas-
dc.contributor.filiacion Filiación Ramírez Agustín, Instituto de Modelización, Experimentación y Tecnología Cardiovascular (Argentina)-
dc.contributor.filiacion Filiación Cabrera-Fischer Edmundo I., Instituto de Modelización, Experimentación y Tecnología Cardiovascular (Argentina)-
dc.date.accessioned Fecha ingreso 2025-10-15T16:52:00Z-
dc.date.available Fecha disponible 2025-10-15T16:52:00Z-
dc.date.issued Año de publicación 2023-
dc.description.abstract Resumen Background: The non-invasive estimation of aortic systolic (aoSBP) and pulse pressure (aoPP) is achieved by a great variety of devices, which differ markedly in the: 1) principles of recording (applied technology), 2) arterial recording site, 3) model and mathematical analysis applied to signals, and/or 4) calibration scheme. The most reliable non-invasive procedure to obtain aoSBP and aoPP is not well established. Aim: To evaluate the agreement between aoSBP and aoPP values invasively and non-invasively obtained using different: 1) recording techniques (tonometry, oscilometry/plethysmography, ultrasound), 2) recording sites [radial, brachial (BA) and carotid artery (CCA)], 3) waveform analysis algorithms (e.g., direct analysis of the CCA pulse waveform vs. peripheral waveform analysis using general transfer functions, N-point moving average filters, etc.), 4) calibration schemes (systolic-diastolic calibration vs. methods using BA diastolic and mean blood pressure (bMBP); the latter calculated using different equations vs. measured directly by oscillometry, and 5) different equations to estimate bMBP (i.e., using a form factor of 33% (“033”), 41.2% (“0412”) or 33% corrected for heart rate (“033HR”). Methods: The invasive aortic (aoBP) and brachial pressure (bBP) (catheterization), and the non-invasive aoBP and bBP were simultaneously obtained in 34 subjects. Non-invasive aoBP levels were obtained using different techniques, analysis methods, recording sites, and calibration schemes. Results: 1) Overall, non-invasive approaches yielded lower aoSBP and aoPP levels than those recorded invasively. 2) aoSBP and aoPP determinations based on CCA recordings, followed by BA recordings, were those that yielded values closest to those recorded invasively. 3) The “033HR” and “0412” calibration schemes ensured the lowest mean error, and the “033” method determined aoBP levels furthest from those recorded invasively. 4) Most of the non-invasive approaches considered overestimated and underestimated aoSBP at low (i.e., 80 mmHg) and high (i.e., 180 mmHg) invasive aoSBP values, respectively. 5) The higher the invasively measured aoPP, the higher the level of underestimation provided by the non-invasive methods. Conclusion: The recording method and site, the mathematical method/model used to quantify aoSBP and aoPP, and to calibrate waveforms, are essential when estimating aoBP. Our study strongly emphasizes the need for methodological transparency and consensus for the non-invasive aoBP assessment.es
dc.format.extent Extensión 21 p.es
dc.format.mimetype Formato application/pdfes
dc.identifier.citation Citación Bia D, Zócalo Y, Sánchez R y otros. Aortic systolic and pulse pressure invasively and non-invasively obtained: Comparative analysis of recording techniques, arterial sites of measurement, waveform analysis algorithms and calibration methods. Frontiers in Physiology [en línea]. 2023;14. 21 p.es
dc.identifier.doi DOI 10.3389/fphys.2023.1113972-
dc.identifier.issn ISSN 1664-042X-
dc.identifier.uri URI https://hdl.handle.net/20.500.12008/52099-
dc.language.iso Idioma enes
dc.publisher Editorial Frontierses
dc.relation.ispartof EN Frontiers in Physiology. 2023;14es
dc.rights Derechos Las obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad de la República.(Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014)es
dc.rights.licence Licencia Licencia Creative Commons Atribución (CC - By 4.0)es
dc.subject Palabras clave Applanation tonometryes
dc.subject Palabras clave Calibrationes
dc.subject Palabras clave Catheterismes
dc.subject Palabras clave Central aortic blood pressurees
dc.subject Palabras clave Invasive records, non-invasive recordses
dc.subject Palabras clave Oscillometryes
dc.subject Palabras clave Vascular ultrasoundes
dc.subject.other Descriptores PRESIÓN ARTERIALes
dc.subject.other Descriptores PRESIÓN SANGUÍNEAes
dc.subject.other Descriptores CALIBRACIÓNes
dc.subject.other Descriptores OSCILOMETRÍAes
dc.subject.other Descriptores VELOCIDAD DEL FLUJO SANGUÍNEOes
dc.title Título Aortic systolic and pulse pressure invasively and non-invasively obtained: Comparative analysis of recording techniques, arterial sites of measurement, waveform analysis algorithms and calibration methodses
dc.type Tipo de documento Artículoes
FicherosDescripciónTamañoFormato
Aortic systolic and pulse pressure.pdf Aortic systolic and pulse pressure 39.26 MB Adobe PDF