Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/20.500.12008/30587
MetadatoEtiquetaValorIdioma
dc.contributor.author Autor De Olivera, Lucía-
dc.contributor.author Autor Fierro, Carla-
dc.contributor.author Autor Gónzalez, Camila-
dc.contributor.author Autor Lema, María Luisa-
dc.contributor.author Autor Pirez, María Sofía-
dc.contributor.author Autor Póppolo, María Fernanda-
dc.contributor.author Autor Moraes, Leandro-
dc.contributor.author Autor Puppo, Corina-
dc.contributor.filiacion Filiación De Olivera Lucía, Universidad de la República (Uruguay). Facultad de Medicina-
dc.contributor.filiacion Filiación Fierro Carla, Universidad de la República (Uruguay). Facultad de Medicina-
dc.contributor.filiacion Filiación Gónzalez Camila, Universidad de la República (Uruguay). Facultad de Medicina-
dc.contributor.filiacion Filiación Lema María Luisa, Universidad de la República (Uruguay). Facultad de Medicina-
dc.contributor.filiacion Filiación Pirez María Sofía, Universidad de la República (Uruguay). Facultad de Medicina-
dc.contributor.filiacion Filiación Póppolo María Fernanda, Universidad de la República (Uruguay). Facultad de Medicina-
dc.contributor.filiacion Filiación Moraes Leandro, Universidad de la República (Uruguay). Facultad de Medicina-
dc.contributor.filiacion Filiación Puppo Corina, Universidad de la República (Uruguay). Facultad de Medicina-
dc.date.accessioned Fecha ingreso 2022-01-04T13:40:23Z-
dc.date.available Fecha disponible 2022-01-04T13:40:23Z-
dc.date.issued Año de publicación 2019-
dc.description Descripción Lucia De Olivera: Estudiante de Medicina, Ciclo de Metodología Científica II, Facultad de Medicina, Universidad de la República, Uruguay.-- Carla Fierro: Estudiante de Medicina, Ciclo de Metodología Científica II, Facultad de Medicina, Universidad de la República, Uruguay.-- Romina Gonzalez: Estudiante de Medicina, Ciclo de Metodología Científica II, Facultad de Medicina, Universidad de la República, Uruguay.-- María Luisa Lema: Estudiante de Medicina, Ciclo de Metodología Científica II, Facultad de Medicina, Universidad de la República, Uruguay.-- María Sofía Pirez: Estudiante de Medicina, Ciclo de Metodología Científica II, Facultad de Medicina, Universidad de la República, Uruguay.-- María Fernanda Póppolo: Estudiante de Medicina, Ciclo de Metodología Científica II, Facultad de Medicina, Universidad de la República, Uruguay.-- Leandro Moraes: Docente supervisor. Centro de Tratamientos Intensivos, Hospital de Clínicas, Universidad de la República, Montevideo, Uruguay.-- Corina Puppo: Docente supervisor. Centro de Tratamientos Intensivos, Hospital de Clínicas, Universidad de la República, Montevideo, Uruguay.-- Contacto: Corina Puppo. Email: coripuppo@gmail.comes
dc.description.abstract Resumen Este estudio busca comparar los valores de presión arterial continua medida de forma invasiva, mediante un catéter arterial, con valores obtenidos por métodos no invasivos (Finapres). Se compararon las diferencias entre presiones sistólicas, diastólicas y medias de ambos métodos de medición con el fin de determinar si el Finapres se puede utilizar como sustituto universal para el monitoreo continuo de la presión arterial, estimando la fiabilidad de la presión no invasiva. Se realizó un estudio observacional transversal en el cual se seleccionó una muestra de 33 pacientes con cateterización arterial, internados en el Centro de Tratamiento Intensivo del Hospital de Clínicas en Montevideo, Uruguay, en los que se colocó además, Finapres. Las salidas digitales de ambas presiones se registraron simultáneamente en una computadora. En 3 pacientes, el Finapres no logró captar señal, mientras que 7 fueron desvinculados del estudio por mal registro de la señal. Por lo tanto, se compararon solo 23 pacientes. La media de la diferencia entre presión arterial media invasiva y no invasiva fue 17,24 mmHg. Para la presión arterial sistólica 27,73 mmHg y para la presión arterial diastólica 19,09 mmHg. Los coeficientes de correlación (r), fueron 0,45 para presión arterial media, 0,40 para presión arterial sistólica y 0,41 para presión arterial diastólica. Dada la pobre correlación existente, se concluye que Finapres en pacientes críticos, no puede sustituir al método invasivo ya que en este grupo es necesario tener un registro continuo de la presión arterial más exacta, con menos errores que los métodos no invasivos.es
dc.description.abstract Resumen This study compares continuous blood pressure values measured invasively, through an arterial catheter, with BP values measured non-invasively through Finapres. Thesystolic, diastolic and mean pressures of both measurement methods were compared through the differences of their mean values, and correlated,in order to determine if Finapres can be used as a universal substitute for continuous blood pressure monitoring. This procedureallowed the identification of theclinical significance and of the reliability of the estimation of the non-invasive pressure measurements. A cross-sectional observational study was made, studying a sample of 33 patients admitted to the Intensive Critical Unit (ICU) of the Hospital de Clínicas, who had invasive arterial catheters because of their clinical status. They were connected also to Finapres, totally non-invasive. The digital outputs of both pressures were simultaneously registered at a computer. In 3 patients, Finapres failed to record signals, while 7 were discarded from the study because of poor signal recording. Therefore, 23 patients were analyzed and compared. The difference between means of invasive and non-invasive arterial blood pressure was 17,24 mmHg. The difference between means of systolic blood pressure was 27,73 mmHg, whereas for the diastolic blood pressure 9,09 mmHg. The correlation coefficients (r), were 0,45 for mean ABP, 0,40 for systolic blood pressure, and 0,41 for diastolic blood pressure. Our results suggest thatFinapres cannot replace the invasive method in critically ill patientsbecause of their poor correlation and the accuracy of the measurements of blood pressure with continuous invasive procedures.es
dc.format.extent Extensión 7 p.es
dc.format.mimetype Formato application/pdfes
dc.identifier.citation Citación De Olivera L, Fierro C, Gónzalez C y otros. Comparación de la medida de presión arterial continua invasiva y no invasiva en pacientes críticos. Anales de Facultad de Medicina [en línea]. 2019;8(s2). 7 p.es
dc.identifier.issn ISSN 2301-1254-
dc.identifier.uri URI https://hdl.handle.net/20.500.12008/30587-
dc.language.iso Idioma eses
dc.publisher Editorial Udelar. FM.es
dc.relation.isformatof Está en formato: pdfes
dc.relation.ispartof EN Anales de Facultad de Medicina. 2019; 8(s2)es
dc.rights Derechos Las obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad de la República.(Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014)es
dc.rights.licence Licencia Atribución/Reconocimiento 4.0 Internacionales
dc.subject Palabras clave Finapreses
dc.subject Palabras clave Comparación de métodoses
dc.subject Palabras clave Cuidados intensivoses
dc.subject Palabras clave Monitorización presión arteriales
dc.subject Palabras clave Pacientes críticoses
dc.subject Palabras clave Comparison of methodses
dc.subject Palabras clave Intensive carees
dc.subject Palabras clave Blood pressure monitoringes
dc.subject Palabras clave Critical patientses
dc.subject.other Descriptores CUIDADOS CRITICOSes
dc.subject.other Descriptores MONITOREO AMBULATORIO DE LA PRESION ARTERIALes
dc.subject.other Descriptores ENFERMOS CRITICOSes
dc.title Título Comparación de la medida de presión arterial continua invasiva y no invasiva en pacientes críticoses
dc.title.alternative Otros títulos Comparison between continuous invasive and continuous non invasive blood pressure measures in critical patientses
dc.type Tipo de documento Artículoes
FicherosDescripciónTamañoFormato
Comparación de la medida de presión arterial continua invasiva y no invasiva en pacientes críticos.pdf Comparación de la medida de presión arterial continua invasiva y no invasiva en pacientes críticos 1.03 MB Adobe PDF

Licencia Creative Commons:

Excepto donde se indique lo contrario, la licencia de este ítem se describe como Atribución/Reconocimiento 4.0 Internacional