Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/20.500.12008/41754
MetadatoEtiquetaValorIdioma
dc.contributor.author Autor Fichtinger, Gabores
dc.contributor.author Autor Gómez, Alvaroes
dc.contributor.author Autor Lasso, Andrases
dc.contributor.author Autor Carbajal, Guillermoes
dc.date.accessioned Fecha ingreso 2023-12-11T19:57:36Z-
dc.date.available Fecha disponible 2023-12-11T19:57:36Z-
dc.date.issued Año de publicación 2013es
dc.date.submitted Fecha de subida 20231211es
dc.description.abstract Resumen Purpose Freehand tracked ultrasound imaging is an inexpensive non-invasive technique used in several guided interventions. This technique requires spatial calibration between the tracker and the ultrasound image plane. Several calibration devices (a.k.a. phantoms) use N-wires that are convenient for automatic procedures since the segmentation of fiducials in the images and the localization of the middle wires in space are straightforward and can be performed in real time. The procedures reported in literature consider only the spatial position of the middle wire. We investigate if better results can be achieved if the information of all the wires is equally taken into account. We also evaluated the precision and accuracy of the implemented methods to allow comparison with other methods. Methods We consider a cost function based on the in-plane errors between the intersection of all the wires with the image plane and their respective segmented points in the image. This cost function is minimized iteratively starting from a seed computed with a closed-form solution based on the middle wires. Results Mean calibration precision achieved with the N-wire phantom was about 0.5mm using a shallow probe, and mean accuracy was around 1.4mm with all implemented methods. Precision was about 2.0mm using a deep probe. Conclusions Precision and accuracy achieved with the N-wire phantom and a shallow probe are at least comparable to that obtained with other methods traditionally considered more precise. Calibration using N-wires can be done more consistently if the parameters are optimized with the proposed cost function.es
dc.identifier.citation Citación Carbajal, G, Lasso, A, Gómez, Á. Fichtinger, G. "Improving N-wire phantom-based freehand ultrasound calibration". International Journal of Computer Assisted Radiology and Surgery 2013, no.8, pp. 1063–1072. https://doi.org/10.1007/s11548-013-0904-9es
dc.identifier.uri URI https://hdl.handle.net/20.500.12008/41754-
dc.language metadata.dc.language enes
dc.rights Derechos Las obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad De La República. (Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014)es
dc.rights.licence Licencia Atribución/Reconocimiento-NoComercial-SinDerivados 4.0 Internacionales
dc.rights.uri Uri de la licencia https://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subject Palabras clave Freehand ultrasoundes
dc.subject Palabras clave Calibrationes
dc.subject Palabras clave N-wire phantomes
dc.subject Palabras clave Accuracyes
dc.subject.other Descriptores Procesamiento de Señaleses
dc.title Título Improving N-Wire Phantom-based Freehand Ultrasound Calibrationes
dc.type Tipo de documento Preprintes
udelar.academic.department Departamento académico Procesamiento de Señales-
udelar.investigation.group Grupo de investigación Tratamiento de Imágenes-
FicherosDescripciónTamañoFormato
CLGF13b.pdf — 868.4 KB Adobe PDF

Licencia Creative Commons:

Excepto donde se indique lo contrario, la licencia de este ítem se describe como Atribución/Reconocimiento-NoComercial-SinDerivados 4.0 Internacional