Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/20.500.12008/42652

Título:

Eleven years of monitoring an ultra-stable 10 V zener-based voltage standard

Otros títulos:

Coordinador:

Director:

Compilador:

Autor:

de Souza, Heriguatí
Trigo, Leonardo
Slomovitz, Daniel

Tutor:

Tipo de documento:

Ponencia

Editor:

Palabras clave:

Descriptores:

Año de publicación:

2015

Contenido:

Resumen:

The long-term behaviour of a voltage standard based on 140 zeners is analyzed. This standard was developed in 2004 and was monitored up to now. Noise and drift are evaluated showing better results than commercial similar devices. This source is used as the National Voltage Standard in the Uruguayan Designated National Metrology Institute (UTE)

Descripción:

8th Brazilian Congress on Metrology (Metrologia 2015)

metadata.articulos.dc.description.uri:

Editorial:

IOP Publishing

EN:

Journal of Physics: Conference Series 733 (2016) 012065

Financiadores:

Citación:

de Souza, H, Trigo, L, Slomovitz, D. "Eleven years of monitoring an ultra-stable 10 V zener-based voltage standard" Journal of Physics: Conference Series 733 (2016) 012065. DOI 10.1088/1742-6596/733/1/012065

Citación:

metadata.articulos.cc.license.name:

ISBN:

e-ISBN:

ISSN:

ISMN:

Otros identificadores:

Cobertura geográfica:

Cobertura temporal:

Departamento académico:

Grupo de investigación:

Licencia:

Licencia Creative Commons Atribución (CC - By 4.0)
FicherosDescripciónTamañoFormato
DTS15.pdf — 1.5 MB Adobe PDF