Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/20.500.12008/42617
MetadatoEtiquetaValorIdioma
dc.contributor.author Autor Pereira Gómez, Marianoel-
dc.contributor.author Autor Arce Rama, Rodrigo-
dc.contributor.author Autor Ferla, Diego-
dc.contributor.author Autor Simón, Diego-
dc.contributor.author Autor Salazar González, María Cecilia-
dc.contributor.author Autor Perbolianachis Duarte, Paula-
dc.contributor.author Autor Costábile Cristech, Alicia-
dc.contributor.author Autor Fajardo Rossi, Álvaro-
dc.contributor.author Autor Aldunate Caramori, Fabián-
dc.contributor.author Autor Nin, Nicolás-
dc.contributor.author Autor Hurtado, Francisco Javier-
dc.contributor.author Autor Iraola, Gregorio-
dc.contributor.author Autor Moreno Karlen, María del Pilar-
dc.contributor.author Autor Moratorio, Gonzalo-
dc.contributor.filiacion Filiación Pereira Gómez Marianoel, Universidad de la República (Uruguay). Facultad de Ciencias. Centro de Investigaciones Nucleares.-
dc.contributor.filiacion Filiación Arce Rama Rodrigo, Universidad de la República (Uruguay). Facultad de Ciencias. Centro de Investigaciones Nucleares.-
dc.contributor.filiacion Filiación Ferla Diego, Universidad de la República (Uruguay). Facultad de Ciencias. Centro de Investigaciones Nucleares.-
dc.contributor.filiacion Filiación Simón Diego, Universidad de la República (Uruguay). Facultad de Ciencias. Centro de Investigaciones Nucleares.-
dc.contributor.filiacion Filiación Salazar González María Cecilia, Instituto Pasteur (Montevideo)-
dc.contributor.filiacion Filiación Perbolianachis Duarte Paula, Universidad de la República (Uruguay). Facultad de Ciencias. Centro de Investigaciones Nucleares.-
dc.contributor.filiacion Filiación Costábile Cristech Alicia, Universidad de la República (Uruguay). Facultad de Ciencias. Instituto de Biología.-
dc.contributor.filiacion Filiación Fajardo Rossi Álvaro, Universidad de la República (Uruguay). Facultad de Ciencias. Centro de Investigaciones Nucleares.-
dc.contributor.filiacion Filiación Aldunate Caramori Fabián, Universidad de la República (Uruguay). Facultad de Ciencias. Centro de Investigaciones Nucleares.-
dc.contributor.filiacion Filiación Nin Nicolás, ASSE-
dc.contributor.filiacion Filiación Hurtado Francisco Javier, ASSE-
dc.contributor.filiacion Filiación Iraola Gregorio, Instituto Pasteur (Montevideo)-
dc.contributor.filiacion Filiación Moreno Karlen María del Pilar, Universidad de la República (Uruguay). Facultad de Ciencias. Centro de Investigaciones Nucleares.-
dc.contributor.filiacion Filiación Moratorio Gonzalo, Universidad de la República (Uruguay). Facultad de Ciencias. Centro de Investigaciones Nucleares.-
dc.date.accessioned Fecha ingreso 2024-02-23T14:43:12Z-
dc.date.available Fecha disponible 2024-02-23T14:43:12Z-
dc.date.issued Año de publicación 2023-
dc.description.abstract Resumen Understanding transmission routes of SARS-CoV-2 is crucial to establish effective interventions in healthcare institutions. Although the role of surface contamination in SARS-CoV-2 transmission has been controversial, fomites have been proposed as a contributing factor. Longitudinal studies about SARS-CoV-2 surface contamination in hospitals with different infrastructure (presence or absence of negative pressure systems) are needed to improve our understanding of their effectiveness on patient healthcare and to advance our knowledge about the viral spread. We performed a one-year longitudinal study to evaluate surface contamination with SARS-CoV2 RNA in reference hospitals. These hospitals have to admit all COVID-19 patients from public health services that require hospitalization. Surfaces samples were molecular tested for SARSCoV-2 RNA presence considering three factors: the dirtiness by measuring organic material, the circulation of a high transmissibility variant, and the presence or absence of negative pressure systems in hospitalized patients’ rooms. Our results show that: (i) There is no correlation between the amount of organic material dirtiness and SARS-CoV-2 RNA detected on surfaces; (ii) SARS-CoV-2 high transmissible Gamma variant introduction significantly increased surface contamination; (iii) the hospital with negative pressure systems was associated with lower levels of SARS-CoV-2 surface contamination and, iv) most environmental samples recovered from contaminated surfaces were assigned as noninfectious. This study provides data gathered for one year about the surface contamination with SARSCoV-2 RNA sampling hospital settings. Our results suggest that spatial dynamics of SARS-CoV-2 RNA contamination varies according with the type of SARS-CoV-2 genetic variant and the presence of negative pressure systems. In addition, we showed that there is no correlation between the amount of organic material dirtiness and the quantity of viral RNA detected in hospital settings. Our findings suggest that SARS CoV-2 RNA surface contamination monitoring might be useful for the understanding of SARS-CoV-2 dissemination with impact on hospital management and public health policies. This is of special relevance for the Latin-American region where ICU rooms with negative pressure are insufficient.es
dc.format.extent Extensión 11 h.es
dc.format.mimetype Formato application/pdfes
dc.identifier.citation Citación Pereira Gómez, M, Arce Rama, R, Ferla, D [y otros autores]. "One-year monitoring SARS-CoV-2 RNA surface contamination in hospitals reveals no correlation with organic material and negative pressure as a limiting factor for contamination". Heliyon. [en línea] 2023, 9(3): e13875. 11 h. DOI: 10.1016/j.heliyon.2023.e13875.es
dc.identifier.doi DOI 10.1016/j.heliyon.2023.e13875-
dc.identifier.issn ISSN 2405-8440-
dc.identifier.uri URI https://hdl.handle.net/20.500.12008/42617-
dc.language.iso Idioma enes
dc.publisher Editorial Cell Presses
dc.relation.ispartof EN Heliyon, 2023, 9(3): e13875es
dc.rights Derechos Las obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad de la República.(Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014)es
dc.rights.licence Licencia Licencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0)es
dc.subject Palabras clave SARS-CoV2 RNAes
dc.subject Palabras clave Ct valuees
dc.subject Palabras clave Fomiteses
dc.subject Palabras clave Organic material dirtinesses
dc.subject Palabras clave ATP measurementses
dc.subject Palabras clave Negative pressure systemes
dc.subject Palabras clave Variant of concernes
dc.title Título One-year monitoring SARS-CoV-2 RNA surface contamination in hospitals reveals no correlation with organic material and negative pressure as a limiting factor for contaminationes
dc.type Tipo de documento Artículoes
FicherosDescripciónTamañoFormato
10.1016j.heliyon.2023.e13875.pdf — 2.51 MB Adobe PDF