| Metadato | Etiqueta | Valor | Idioma |
|---|---|---|---|
| dc.contributor.author | Autor | Berrutti, Fernando | es |
| dc.contributor.author | Autor | Giusto, Alvaro | es |
| dc.contributor.author | Autor | Artenstein, Michel | es |
| dc.date.accessioned | Fecha ingreso | 2023-11-14T17:04:24Z | - |
| dc.date.available | Fecha disponible | 2023-11-14T17:04:24Z | - |
| dc.date.issued | Año de publicación | 2012 | es |
| dc.date.submitted | Fecha de subida | 20231114 | es |
| dc.description | Descripción | Trabajo presentado al 2012 Sixth IEEE/PES Transmission and Distribution: Latin America Conference and Exposition (T | es |
| dc.description | Descripción | D-LA), Montevideo, Uruguay, 2012 | es |
| dc.description.abstract | Resumen | This work aims the description, modeling and simulation of the incorporation of a power system stabilizer (PSS) in variable speed wind turbines in order to dampen oscillation in power grids. The proposed PSS aims to alter the nature of the electric power injected by the wind farms to, in some sense, mimic the oscillatory behavior of synchronous generators and allows dampening these transient oscillations. The main advantage of this stabilizing action lies in the fact that the wind turbines, by decoupling the electrical frequency of the network respect its rotational speed by the inclusion of power electronic converters, allows the injection of oscillating power without risk of suffering stability issues. This allows to improve the oscillation damping between different synchronous generators.The proposed PSS has been analyzed in a grid of three areas: an area comprises the infinite bus; the second one a synchronous generator and the third one contains a synchronous generator and a wind farm. The PSS takes as reference the active power injected by the synchronous generator of the third area using synchrophasors. Finally, it is studied the performance of the PSS for a particular case of the Uruguayan power grid. In this scenario, the second area is composed by the hydro power plant Baygorria; the third area is comprised by the hydro power plant Terra and the wind farms Palmatir and Agua Leguas; finally, the first area is the rest of the power system. | es |
| dc.identifier.citation | Citación | Berrutti, F, Giusto, A, Artenstein, M. "Design of power system stabilizers in variable speed wind generators using remote signals." Publicado en: 2012 Sixth IEEE/PES Transmission and Distribution: Latin America Conference and Exposition (T | es |
| dc.identifier.citation | Citación | D-LA), Montevideo, Uruguay, 2012, pp. 1-8, doi: 10.1109/TDC-LA.2012.6319076. | es |
| dc.identifier.uri | URI | https://hdl.handle.net/20.500.12008/41126 | - |
| dc.language | metadata.dc.language | en | es |
| dc.rights | Derechos | Las obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad De La República. (Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014) | es |
| dc.rights.licence | Licencia | Licencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0) | es |
| dc.subject | Palabras clave | Angle stability | es |
| dc.subject | Palabras clave | Power system stabilizers | es |
| dc.subject | Palabras clave | PMU | es |
| dc.subject | Palabras clave | Variable speed wind turbines | es |
| dc.subject | Palabras clave | Wind farms | es |
| dc.title | Título | Design of power system stabilizers in variable speed wind generators using remote signals | es |
| dc.type | Tipo de documento | Ponencia | es |
Colecciones:
| Ficheros | Descripción | Tamaño | Formato | ||
|---|---|---|---|---|---|
| BGA12.pdf | — | 769.39 KB | Adobe PDF |