Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/20.500.12008/25978

Título:

Evaluación de la resistencia de unión a dentina humana de un sistema adhesivo universal con clorhexidina utilizado en modo de grabado total y autocondicionante

Otros títulos:

Human dentin bond strength of chlorhexidine containing universal adhesive system used in total-etch and self-etch modes

Coordinador:

Director:

Compilador:

Autor:

Tessore, Romina
Silveira, Camila
Vázquez, Priscila
Mederos, Matías
García Terra, Andrés
Cuevas-Suárez, Carlos Enrique

Tutor:

Tipo de documento:

Artículo

Editor:

Palabras clave:

Clorhexidina
Microtracción
Metaloproteinasas
Capa híbrida.

Descriptores:

Año de publicación:

2020

Contenido:

Resumen:

Objetivos: Evaluar la resistencia de unión a la microtracción en dentina humana de un sistema adhesivo universal con clorhexidina en su composición, en modo de grabado y lavado en 2 pasos, y en modo de autograbado. Metodología: 20 terceros molares divididos aleatoriamente en 4 grupos según el tipo de sistema adhesivo utilizado (Single Bond Universal®, 3MESPE y Peak Universal Bond®, Ultradent Products) y modo de uso (grabado total y autograbado). Se confeccionaron cuerpos de prueba sometidos al ensayo de microtracción utilizando una máquina de ensayos universales. Resultados: No se encontraron diferencias estadísticamente significativas entre los cuatro grupos estudiados. Conclusiones: La resistencia de unión de una resina compuesta a dentina humana no fue afectada por el uso de un sistema adhesivo universal que contiene clorhexidina en su composición aplicado en los modos de grabado total y autograbado.
Objectives: To evaluate the microtensile bond strength to human dentin of chlorhexidine containing universal adhesive system applied in the total-etch and selfetch modes. Methods: Twenty third molars were randomly divided into four groups according to the universal adhesive system (Single Bond Universal ®, 3M ESPE and Peak Universal Bond®, Ultradent) and application mode used (total-etch and self-etch). Specimens were prepared and subjected to a microtensile bond strength using a MTS SANS universal testing machine. Results: No statistically significant differences were found in the microtensile bond strength between the four groups studied. Conclusions: The bond strength of a composite resin to human dentin was not affected by the use of a universal adhesive system with chlorhexidine in its composition applied in the total-etch and self-etch modes.

Descripción:

metadata.articulos.dc.description.uri:

Editorial:

EN:

Odontoestomatología. Vol. XXII - Nº 35 / Enero - Junio 2020

Financiadores:

Citación:

Tessore, R, Silveira, C, Vázquez, P, y otros. "Evaluación de la resistencia de unión a dentina humana de un sistema adhesivo universal con clorhexidina utilizado en modo de grabado total y autocondicionante" Odontoestomatología. [en línea] Vol. XXII - Nº 35 / Enero - Junio 2020

Citación:

metadata.articulos.cc.license.name:

ISBN:

e-ISBN:

ISSN:

ISMN:

Otros identificadores:

Cobertura geográfica:

Cobertura temporal:

Departamento académico:

Grupo de investigación:

Licencia:

Licencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0)

Colecciones:

FicherosDescripciónTamañoFormato
Tessore.pdf — 751.06 KB Adobe PDF