Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/20.500.12008/55245
MetadatoEtiquetaValorIdioma
dc.contributor.author Autor Pereira, Valeria-
dc.contributor.author Autor Bertalmio, Martín-
dc.contributor.author Autor Pérez De Palleja, Martín-
dc.contributor.author Autor Duarte, Leticia-
dc.contributor.filiacion Filiación Pereira Valeria, Universidad de la República (Uruguay). Facultad de Medicina. Departamento de Anestesiología-
dc.contributor.filiacion Filiación Bertalmio Martín, Universidad de la República (Uruguay). Facultad de Medicina. Departamento de Anestesiología-
dc.contributor.filiacion Filiación Pérez De Palleja Martín, Universidad de la República (Uruguay). Facultad de Medicina. Departamento de Anestesiología-
dc.contributor.filiacion Filiación Duarte Leticia, Universidad de la República (Uruguay). Facultad de Medicina. Departamento de Anestesiología-
dc.date.accessioned Fecha ingreso 2026-05-28T14:57:40Z-
dc.date.available Fecha disponible 2026-05-28T14:57:40Z-
dc.date.issued Año de publicación 2022-
dc.description.abstract Resumen Valorar las alteraciones de la variabilidad de la frecuencia cardíaca fetal (FCF) luego de la inducción de analgesia del parto neuroaxial. Ensayo clínico prospectivo analítico de cohortes realizado entre julio de 2020 y julio de 2021, con 59 embarazadas del Centro Hospitalario Pereira Rosell (CHPR) que cumplieron con los criterios de inclusión. Se asignó de forma aleatoria la técnica analgésica (epidural/espinal-epidural). Se monitorizó durante 20 minutos la FCF, presión arterial materna (PA), intensidad de la contracción uterina en Unidades Montevideo (UM) y dolor mediante escala numérica verbal (EVA). Para la FCF en cada uno de los tiempos no se observaron diferencias estadísticamente significativas, ni hubo casos de bradicardia fetal. En la PA y UM no se observaron diferencias estadísticamente significativas. Para la EVA en cada uno de los tiempos no se observaron diferencias estadísticamente significativas, excepto inmediatamente a recibir la analgesia, valor p = 0,046. La CSE no se asoció a mayor riesgo de alteraciones de la FCF. El fentanil intratecal a dosis máxima de 15 mcg es seguro y efectivo para calmar el dolor del trabajo de parto. El alivio del dolor fue similar para los 2 grupos. No se observaron episodios de hipotensión. Ambas técnicas son eficaces para el alivio del dolor con similar perfil de seguridad cuando se usan dosis bajas de fentanil intrarraquídeo.es
dc.description.abstract Resumen To assess changes in fetal heart rate variability (FHR) after induction of neuraxial labor analgesia. Prospec- tive analytical cohort clinical trial conducted between July 2020 and July 2021, with fifty-nine pregnant women from the Pereira Rossell Hospital Center (CHPR) who met the inclusion criteria. Analgesic technique (epidural/spinal epidural) was randomly assigned. FHR, maternal blood pressure (BP), intensity of uterine contraction in Montevideo Units (UM) and pain using a verbal numerical scale (VAS) were monitored for 20 minutes. No statistically significant differences were observed for FHR at each of the times, and there were no cases of fetal bradycardia. In PA and UM, no statistically significant differences were observed. No statistically significant differences were observed for VAS at each of the times, except immediately after receiving analgesia, p value = 0.046. CSE was not associated with a higher risk of FHR alterations. Intrathe- cal fentanyl at a maximum dose of 15 mcg is safe and effective in relieving labor pain. Pain relief was similar for the two groups. No episodes of hypotension were observed. Both techniques are effective for pain relief with a similar safety profile when low doses of intraspinal fentanyl are used.es
dc.format.extent Extensión 5 p.es
dc.format.mimetype Formato application/pdfes
dc.identifier.citation Citación Pereira V, Bertalmio M, Pérez De Palleja M y otros. Incidencia de alteraciones de la frecuencia cardíaca fetal tras la inducción de analgesia del parto neuroaxial. Revista Chilena de Anestesia [en línea]. 2022;51(6):671-677es
dc.identifier.doi DOI 10.25237/revchilanestv5130091424-
dc.identifier.eissn e-ISSN 0719-6792-
dc.identifier.uri URI https://hdl.handle.net/20.500.12008/55245-
dc.language.iso Idioma eses
dc.publisher Editorial Sociedad de Anestesiología de Chilees
dc.relation.ispartof EN Revista Chilena de Anestesia. 2022;51(6):697-701es
dc.rights Derechos Las obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad de la República.(Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014)es
dc.rights.licence Licencia Atribución/Reconocimiento 4.0 Internacionales
dc.rights.uri Uri de la licencia https://creativecommons.org/licenses/by/4.0/-
dc.subject Palabras clave Frecuencia cardíaca fetales
dc.subject Palabras clave Fetal heart ratees
dc.subject Palabras clave Analgesia neuroaxiales
dc.subject Palabras clave Neuroaxial analgesiaes
dc.subject Palabras clave Bradicardiaes
dc.subject Palabras clave Bradycardiaes
dc.subject Palabras clave Variabilidades
dc.subject Palabras clave Variabilityes
dc.subject.other Descriptores PARTOes
dc.subject.other Descriptores ANESTESIA EPIDURALes
dc.subject.other Descriptores FETOes
dc.subject.other Descriptores FRECUENCIA CARDÍACAes
dc.title Título Incidencia de alteraciones de la frecuencia cardíaca fetal tras la inducción de analgesia del parto neuroaxiales
dc.title.alternative Otros títulos Incidence of fetal heart rate abnormalities after neuroaxial labor analgesia inductiones
dc.type Tipo de documento Artículoes
FicherosDescripciónTamañoFormato
Incidencia de alteraciones de la frecuencia cardíaca fetal.pdf Incidencia de alteraciones de la frecuencia cardíaca fetal 2.26 MB Adobe PDF

Licencia Creative Commons:

Excepto donde se indique lo contrario, la licencia de este ítem se describe como Atribución/Reconocimiento 4.0 Internacional